Product Features
123
© 2017, ATEÏS, member of PAX ProAV Group
Leakage Monitor Enable: A check box used to enable or disable the leakage detect function.
Leakage Threshold (1k ohm): A threshold value for the leakage detection. If the leakage
impedance is lower than this value, the fault Leakage Occurrence is detected.
Leak Open Relay Enable: Open the relay setting when the fault Leakage Occurrence is detected in
the system.
Leak Open Threshold (1k ohm): A threshold value for the leakage detection. If the leakage
impedance is lower than this value, the leak open.
Global Leakage Monitor Enable: If users want to enable the monitoring function on all the
connected IDA8 processors, you need to click the [Global Leakage Monitor Enable] option first,
and change the [Leakage Monitor Enable] option either by clicking to enable this function or
unclick to cancel the monitoring function.
Global Leakage Threshold: If users want to enable the monitoring function on all the connected
IDA8 processors, you need to click the [Global Leakage Threshold] option first, and change the
[Leakage Threshold 1k ohm] option either by clicking to enable this function or unclick to cancel
the monitoring function.
Global Leakage Open Relay Enable: If users want to enable the monitoring function on all the
connected IDA8 processors, you need to click the [Global Leakage Open Relay Enable] option
first, and change the [Enable Leakage Open Relay] option either by clicking to enable this function
or unclick to cancel the monitoring function.
Global Leakage Open Threshold: If users want to enable the monitoring function on all the
connected IDA8 processors, you need to click the [Global Leakage Open Threshold] option first,
and change the [Leakage Open Threshold 1k ohm] option either by clicking to enable this
function or unclick to cancel the monitoring function.
Monitoring Checkbox: Select the checkbox to activate the channel usage of amplifier.
Measurement: