IDA8 Global-Net User Manual
26
© 2017, ATEÏS, member of PAX ProAV Group
Touch Screen:
A 3.5" color touch panel allows a graphical interface for users to control or read the status of system.
Parameters or settings of the device can be adjusted from multiple layered on the menu.
ESC Button:
Navigate as Prev/Back/Leave action.
OK Button:
Navigate as Start/Next/Save action.
Up/Down button:
Navigate as Up/Down arrow control action.
Plus/Down Button:
Navigate as Volume Up/Down action.
To know more details about the LCD Front Panel Menu, please go to
chapter.
Zone EVAC LEDs:
To show the audio channel is in EVAC paging or not. Each LED corresponds to an output channel of
Network Paging component. For example, 1st LED is for pin M1, 2nd LED for pin M2 and so on.
We strongly recommend to connect the Monitor C component and Monitor D component
connect to M1~M8 on Network Paging component, or it might cause the zone selection and its
EVAC LED will not corresponded.
Zone Fault LEDs:
This LED will light up if one of following faults is detected:
o
Normal AMP Error
o
Line A Error
o
Line B Error
o
Backup AMP Error
o
AMP Line Leakage Error
EVAC Reset Button:
Cancel the event triggered by EVAC button.
Power LED:
This LED will light up when the IDA8C is power on.
Network LED:
This LED will light up if there are more than two deployed IDA8 processors in Ateis-Net.
EVAC Button:
To trigger an event bind with this button.