System Functionality
343
© 2017, ATEÏS, member of PAX ProAV Group
Assuming there's a 3dB level bar, and after proceeding Compile, Store and Download Config
action, the user has change the level from 3dB to 5dB under the Online status.
o
However, if user has rebooted the processors/devices, the actual level of device will still be
3dB.
o
If user wants to keep the level parameter as 5dB even the processors/devices are rebooted,
please adjust the level under the Online status and click [Save Parameter] button, then the
actual level of device will be 5dB. But if proceeding the Download Config action now, the
level will be as 3 dB due to the reason that the [Save Parameter] function will not replace the
original configuration. If user wants to change the level to 5dB, please click Online button.
o
If user wants to keep the level as 5dB even proceeding Download Config action, please
change the current level to 5dB, and click Compile and Store button.
Please note the following circumstances are required to click the [Save Parameter] button:
1. When finishing the [Get Reference] action for the amplifier loudspeaker on the monitoring
window, the monitoring value will not be automatically saved in the IDA8 system, therefore,
please click [Save Parameter] button.
2. Click [Save Parameter] button after the calibration of DNM-485/DNM-ENET is completed.
4.1.10 Tools
Language:
Choose the software language either
English or Simplified Chinese.
Tool: Change the skin style(color and appearance) on Ateis Studio windows.
Office 2003 Blue
Mc Skin
: