Product Features
67
© 2017, ATEÏS, member of PAX ProAV Group
system.
Backup Sharing Amplifier:
If one of the normal amplifiers fail, one backup
amplifier can take over immediately. In the
meantime, the unit will quickly switch from the failed
amplifier. Based on this concept, the IDA8 system
provides a flexible mechanism for amplifier backup.
One backup amplifier can service multiple zones.
The preview figure demonstrates how a backup
amplifier works when a normal amplifier connected
to Zone 2 fails. The backup amplifier can serve Zone
1 to Zone 4.
Backup Sharing Am plifier
Advance Backup Amplifier Setup:
An Ateis Net system consists of one IDA8C and two
IDA8S's. There are 24 zones in the system divided
into three backup amplifier groups. For each group,
there is a backup amplifier which becomes
redundant if any of the normal amplifiers in the group
fail. To group zones, you need to wire AMP I and
AMP O between the backup amplifier connectors.
Red lines show the wire connections to group zones.
There are three backup amplifier groups in the
above figure:
o
Backup Group1: Amplifier B1 serves Zone1 ~
Zone8.
o
Backup Group2: Amplifier B2 serves Zone9 ~
Zone12.
o
Backup Group3: Amplifier B3 serves Zone 13 ~
zone24.
Advance Backup Am plifier Setup