DSP Components
459
© 2017, ATEÏS, member of PAX ProAV Group
Drag the URGP device icon from the configuration file,
and connect it to PDC port. See the picture on the
right.
Double click the URGP device icon to open a setting
window, them you can choose which URGP
component you want to connect to. See the picture
on the right.
Control Window
Parameters
Monitor Mode: Enable/disable the external device monitoring. If this option is enabled, it needs
two 4.7k Ohm resisters in the external device circuit.
Type: Specify the mode of activation. There are two choices:
o
Open(Lo): Normally open, close the contact to the output signal.
o
Close(Hi): Normally close, open the contact to the output signal.
Status: Show states of the external device. There are four states:
o
Open: An open circuit of external device is detected.
o
Short: A short circuit of external device is detected.
o
Activate: The logic output is active.
o
Deactivate: The logic output is deactivated.
5.13.10 Event
5.13.10.1 Trigger
This component links the events to the logic signal, which the events will be triggered if the input logic
signal is from Low to High or from High to Low depending on the settings.