IDA8 Global-Net User Manual
68
© 2017, ATEÏS, member of PAX ProAV Group
Software settings:
1. Right click on IDA8C1 block in devices
window, then click [Monitor] option to open
[Monitor(Matrix Mode) - IDA8C1] window.
2. Select [Backup Amplifier Monitor].
3. Click [Amplifier Amount] button.
The picture on the right shows the setting
window for backup configuration in the Advance
Backup Amplifier Setup:
Amount: The number of backup amplifiers in
system. The list content of the combo box in
an amplifier depends on this value. For
example, if Amount = 3, then the list content
should be none (zero), 1, 2, 3.
Field [Device] of Grid: List the devices in the
same Ateis netwok.
Field [Zone Board] of Grid: List the zone
boards of the device. Zone Board1 means
Zone1 to Zone4, Zone board2 means Zone5
to Zone8.
Field [Amplifier] of Grid: Set the group
without zones. In the above figure, IDA8S1
Zone board1(Zone1~Zone4 of IDA8S1),
IDA8S2 Zone Board1(Zone1~4 of IDA8S2),
IDA8S2 Zone Board2(zone 5~8 of IDA8S2) are
the same value (i.e. those zones are the same
group and use the same amplifier for
backup).
3.1.9
Monitoring Fault
For security purposes, the IDA8 is designed to monitor the connected equipments. When an error is
detected, a fault will be generated to inform the user. Then user can change the non-working equipment
quickly to make the system function correctly again.
There are two types of faults:
System Fault:
This sort of fault is about the internal error of the IDA8C/S. In most of cases, it is a hardware failure and
the board inside the device needs to be changed o repaired.
G.Fault:
The G.Fault LED lights up for mostly all faults.