System Functionality
389
© 2017, ATEÏS, member of PAX ProAV Group
'S TX' +
I
R001
3
+ 'E XT' + 'CS ' + 'CR '
'S TX' +
I
R001
3
+ 'E XT' + 'CR '
4.5.1.5.1.2 Write Parameter Command
Command string = W nnnn vvvv
S TX
Data S ec tion
STX
W nnnn v v v v
EXT
CS
CR
S TX
Data S ec tion
STX
W nnnn v v v v
EXT
CR
nnnn = function name (fixed 4 length)
v v v v = value (unfixed)
For example: cd1, value = 10 dB
'S TX' +
W
CD1
10
+ 'E XT' + 'CS ' + 'CR '
'S TX' +
W
CD1
10
+ 'E XT' + 'CR '
4.5.1.5.1.3 Read Parameter Command
Command string =Rnnnn
S TX
Data S ec tion
STX
Rnnnn
EXT
CS
CR
S TX
Data S ec tion
STX
Rnnnn
EXT
CR
nnnn = function name (fixed 4 length)
Answer is always Rnnnnv v v v (Rep ly Read Para. Com.)
4.5.1.5.1.4 Connect Test Command
Command string = T
S TX
Data S ec tion
STX
T
EXT
CS
CR
S TX
Data S ec tion
STX
T
EXT
CR
Answer is always ACK CR or None, depend on communication protocol settings.
4.5.1.5.1.5 Control Command (IDA8)
1. Chang e Preset
command string = Mvvvv
S TX
Data S ec tion
STX
Mv v v v
EXT
CS
CR
S TX
Data S ec tion
STX
Mv v v v
EXT
CR
v v v v = Master preset number
2. Load S ub -Preset
command string = Svvvv
S TX
Data S ec tion
STX
S v v v v
EXT
CS
CR