IDA8 Global-Net User Manual
298
© 2017, ATEÏS, member of PAX ProAV Group
3.2.13.2.2 Fault LED
Issue: The CD-TOUCH is unable to connect by Ateis Studio
The situation happens when the CD-TOUCH has lost communication with audio processor.
Please follow the instruction in [How to Solve] chapter and check whether the solution meets your
requirements.
The LED indicators:
When the FAULT LED blinks
The FAULT LED blinks when the PSS-AS has lost communication with audio processor. First, check
the information and diagnosed description displayed on [Status Bar] of PSS AS, then move to the
following steps listed below and find out the solution that meets your problem.
1. Check whether the PSS AS has been connected with audio processor in the configuration
table.
2. Check whether the RS485 protocol on [Machine Setting] function has been selected to [PSS/
RWD AIO] option, and meets your installed port for PSS AS. (this setting is only for Ateis Global
version software)
3. If the device still cannot work with the audio processor, it might result from the broken device
or cables. When facing this problem, please contact our Ateis Local personnel.
3.2.14 CD8