When a fault is generated, the following will be performed by the IDA8C/S:
Fault State Output contact open (When a major fault occurs).
Log the fault.
A warning message of the fault will be shown in the touch screen panel.
When Ateis Studio is connected to the IDA8C/S, in [Device Status] field of [Device Management]
panel will show a fault, see the picture as below.
There is a warning tone generated by the monitoring speaker.
And a text message shown in the PSS touch screen panel, see the picture as below.
3.1.9.1
Table of Global Faults
Name
Description
Solution Way
The Ethernet connection fails.
(If the ethernet monitoring is enabled in ATEIS
Studio)
Check ethernet cable
This fault happens when the "Fault Define" DSP
component received a logic signal from the input.
Check trigger source
The audio cable for Fireman and PDC port turns
short circuit or cuts off.
Check audio cable
1. Amplifier gain is too high.
2. Amplifier gain is too low.
3. Amplifier fails.
Check amplifier power, line
1. Line A/B Open, a speaker is not connected to
IDA8C/S.
2. Line A/B Bad Impedance, the impedance of the
speakers is changed over the tolerance.
3. Line A/B short, a circuit outside the speaker zone
output connector is shorted, and no sound
comes out. This fault may damage the amplifier.
Check speaker line A / B
The measurement of speaker lines has short-circuit
fault due to the + speaker line is connected to
ground wire, and - is connected to ground wire.
Check amplifier & speaker line
SMTP Server
Error
SMTP xxx Connect Fail
SMTP xxx No Response
SMTP xxx HELO Fail
SMTP xxx EHLO Fail
SMTP xxx Authentication Fail
SMTP xxx Username Fail
SMTP xxx Password Fail
SMTP xxx FROM Fail
SMTP xxx TO Fail
SMTP xxx Data Fail (xxx = ip address)
The voltage of EVAC input is not in the range
(when the evacuation input is set to "contact
Check EVAC input line