IDA8 Global-Net User Manual
546
© 2017, ATEÏS, member of PAX ProAV Group
o
If Imax b (mains not present) is less than 100A, use batteries with a capacity of 65 to 225Ah,
and set daughter board jumper on ‘50’.
The following batteries have been approved:
o
Fiamm FG Series
o
Yuasa NP Series
o
Effekta BTL Series
o
Powersonic GB Series
o
Long GB Series
o
Sun FT Series
o
Enersys VE Series
o
ABT TM Series
Note: If you would like to use another battery type, please let us approve them.
Environmental Specifications:
o
Operating temperature: -5 °C to +45 °C at 12 A.
o
Altitude : The max operating temperature decreases of 5°C every 1000 m when over 2000m.
o
Storage temperature: -25 to +85 °C.
o
Operating relative humidity: 20 to 95 % without condensation,
o
Storage relative humidity: 100 to 95 %.
Summary of Available Equipment
Battery Test:
o
The battery presence test is performed in the following manner: every 30 seconds for the first
20 minutes after commissioning and every 15 minutes after. As soon as a fault is detected, the
test is performed every 30 seconds until 20 minutes after the fault disappears.
o
The impedance measurement test occurs every 4 hours if the mains is present on the power
supply and if his current is < 12A. The impedance limit value is 13 mW ±10 % in 24V and 26
mW ±10% in 48V.
Temperature Compensation:
A battery voltage compensation system maintains the charge characteristics within the limits
specified by the battery manufacturer across the entire operational temperature range.
Battery Low Voltage Protection:
o
The battery low voltage protection threshold is 21,6 V ±3 % (SON 24V 12A MS150 RACK) or
43.2 V ±3 % (SON 48V 12A MS150 RACK).
o
The element causing the cut-out will be in the + position.
Battery Reverse Connection Protection:
o
At start-up: the battery relays will not close.
o
During operation: the fuse F8 will blow out.
Maintenance:
In order to ensure maximal and durable service, we strongly recommend that your product must
be maintained clean and ensure that it is installed in a dry and ventilated location. We shall in no
case be liable for damages associated with improper use or incorrect maintenance of the
equipment.