About This Manual
15
© 2017, ATEÏS, member of PAX ProAV Group
adequate cables.
Do not use benzene, thinner, or chemicals to clean the device. Use only a soft, dry cloth.
If the device is moved from a cold place (e.g., overnight in a car) to a warmer environment,
condensation may form inside the unit, which may affect performance. Allow the device to
acclimatize for about one hour before use.
1.2
System Overview
The IDA8 system offers a fully digital and networked PA/VA system which is EN54-16 and UL2572
certified and UL60065 listed. The IDA8C controller can be used in any installation size, whether is a small
local system of 256 speaker zones or a big complex multi-zone and multi-input system of 8,192 zones.
The IDA8 system has network redundancy on many levels, including the local/global network
redundancy, back-up amplifier switching/sharing, system unit back-up redundancy.
1.3
EC Declaration of Conformity