DSP Components
469
© 2017, ATEÏS, member of PAX ProAV Group
5.13.23 Scheduler
Allows to arrange the timing of generating logical pulse to output. The length of pulse is 1 sec. There are
four types of schedulers: Scheduler 1 CH, Scheduler 2 CH, Scheduler 4 CH and Scheduler 8 CH.
The pins on the top side enables(signal = 1) or disables(signal = 0) the scheduler belongings to the
channel. The pins at the button will generate the pulse signal depending on the settings of component.
Control Window
Scheduler List
Change the channels of scheduler from Scheduler
List.
General Settings
Name:
The
name
of
Scheduler.
Start Time
The start time of the
scheduler.
Stop Condition
Specify the condition to stop a Scheduler. There are three types
of condition:
Continue: In this option, scheduler will never stop. The
triggering setting is always valid.
Number of Times: Scheduler is triggered N times using
triggering setting where N can be set at "Number of Times
parameter".
Stop Time: Scheduler is activated from start time to the
time which set in the "Stop Time parameter".