IDA8 Global-Net User Manual
342
© 2017, ATEÏS, member of PAX ProAV Group
4.1.9.1
Realtime Parameters
The parameters of components can be adjusted realtime under the Online status such as the
component values including monitoring parameters, the action in the checkbox, level bar, level or
source on the rotary knob etc..
Download Config: The [Download Config] function is located at Device Management, see the
picture as below. The Download Config function allows to retrieve the parameters that are stored
in the Ateis devices. Please note this Download Config action does not contain to retrieve the
parameters that saves under the Online status.
Online: The Online action is located at Tools bar, see the picture as below. Online action allows to
read the current parameters of Ateis devices. Please note the parameters might be different from
the parameters after proceeding Download Config action.
The adjustment of realtime parameters can be either done before the Store action, or adjust it directly
after Online. The difference between the two are as below:
1. The parameters that are saved before proceeding the Store action: The Download Config action
will not retrieve the parameters that saves under the Online status, the parameters will still remain
the same.
2. The parameters that are saved under the Online status: Parameters will not be stored in the
devices automatically after rebooting the processors/devices, they will still change back to the
previous parameters.
3. If users would like to store the parameters under the Online status, please click the [Save
Parameter] button. Please note if this button is clicked, the parameter will not change back to the
parameters that are stored in the Download Config configuration.
4. If users would like to replace the original parameters with the current parameters, please proceed
the steps as below:
1) Proceed the action of realtime parameters.
2) Click Offline button.
3) Then click Compile and Store button.
Example 1:
Assuming there's a 3dB level bar, and after proceeding Compile, Store and Download Config
action:
o
The level parameters will still remain as 3dB.
Assuming to change the level parameters from 3dB to 5dB under the Online status, then click
Download Config:
o
The level parameter will still go back to 3dB. But if clicking [Online] button now, the level will
change to 5dB then.
Example 2: