Product Features
95
© 2017, ATEÏS, member of PAX ProAV Group
LED Indicator: When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays at the touch screen of the IDA8C:
"SSI error"
A text message displays at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Contact your technician to repair the device.
3.1.9.2.2 No Parameter Table
The IDA8 can't find the DSP parameters.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays at the touch screen of the IDA8C:
"No Parameter Table"
A text message displays at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Restore the parameters again.
3.1.9.2.3 Flash Error
The Nand flash inside the IDA8C/S has an error.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
System Fault LED on the front panel of the IDA8C/S.
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays on the touch screen of the IDA8C as:
"Flash Error"
A text message displays at the [Machine Fault Record] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.