[Appendix 2] Introduction to Renewal Tool
Appendix 2-85
(2) For secondary replacement
The following parameters are a minimum number of parameters that need to be set for secondary
replacement. Depending on the settings of the currently used servo amplifier, parameters other than
these may need to be set. For details,
refer to Part 2 Section 3.6
.
Parameter
number
Setting item
Setting value
Description
Before
changing
(Note 1)
After
changing
Changing required.
PC22
Function selection C-1
_ 1 _ _ h
_ 0 _ _ h
Serial encoder selection.
This setting is for communication with the encoder of MR-J4. An
incorrect setting causes encoder initial communication data error 1
(AL.20.1).
Position control mode only
PA21
Electronic gear selection
0001h
3001h
J2S electronic gear setting value compatibility mode
* For [Pr. PA06] or [Pr. PA07], the value when performing the
primary replacement is required to be maintained.
Magnify the electronic gear setting value by 32 times.
Speed control mode only
PC12
Analog speed command -
Maximum speed
0
3000
Analog speed command - Maximum speed
The setting value at left is for when the HC-SFS53 motor is replaced
with the HG-SR52 motor.
Torque control mode only
PC12
Analog speed limit - Maximum
speed
0
3000
Analog speed limit - Maximum speed
The setting value at left is for when the HC-SFS53 motor is replaced
with the HG-SR52 motor.
When using encoder output pulses
PA15
Encoder output pulses
4
(Note 3)
128
Used to set the encoder pulses (A-phase and B-phase) output by the
servo amplifier.
An output pulse is required to be set.
PC19
Encoder output pulse setting
selection
0 _ 1 _ h
(Note 3)
1 _ 1 _ h
Encoder output pulse setting selection
Used to set the encoder pulses output by the servo amplifier.
The setting value at left is according to the dividing ratio setting.
Note 1. Setting example at primary replacement.
2. The value is for when the electronic gear setting of an existing servo motor (encoder resolution: 131072 pulses/rev) is "8/1".
3. The value is for when the output pulse setting of an existing HC-KFS motor (encoder resolution: 131072 pulses/rev) is "Dividing
ratio: 1/4".
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...