[Appendix 2] Introduction to Renewal Tool
Appendix 2-11
(5) Encoder
*When the renewal tool is used.
Item
MR-J2S series
MR-J4 series
When the renewal
tool is used
Compatibility
(*)
Remarks
Encode
r
Connector
1 pcs.
1 pc, different connector shape
With conversion
cable
○
Communication
method
Serial communication
Serial communication
○
Resolution 131072
pulses/rev
4194304
pulses/rev
△
(Note)
○
: Compatible;
△
: Limited functions or compatible with certain conditions;
×
: Incompatible
Note. Similar operation is possible using parameter settings. For details about parameter settings, refer to Part 2 for general-purpose
interfaces, Part 3 for SSCNET interfaces, and Part 4 for built-in positioning. For the MR-J4-_B-RJ020 servo amplifier, if the HG
series servo motor is used, the encoder resolution per rotation of the servo motor is not 4194304 pulses/rev but becomes 131072
pulses/rev.
(6) Servo motor
*When the renewal tool is used.
Item
MR-J2S series
MR-J4 series
When the renewal
tool is used
Compatibility
(*)
Remarks
Servo
motor
Connector
(power
supply/brake)
HC-KFS
HG-KR (different connector shape)
With conversion
cable
○
HC-MFS
HG-MR (different connector shape)
○
HC-SFS
HG-SR (different connector shape)
△
(Note 1)
HC-RFS HG-RR
○
HC-LFS
HG-JR (different connector shape)
△
(Note 1)
HC-UFS(B) 2000 r/min
HG-UR
○
HC-UFS(B) 3000 r/min
HG-KR (different connector shape)
○
HA-LFS (7 kW or less)
HG-SR (different connector shape)
○
HA-LFS (11 kW or more)
HG-JR (different connector shape)
△
(Note 2)
(Note 3)
(Note 4)
Note 1. Laying a new electromagnetic brake cable is required when performing a secondary replacement or simultaneous replacement
of a motor with brake.
2. If the HA-LFS motor is replaced with the HG-JR motor, it is necessary to change the crimp terminal of the existing power
supply cable.
Refer to Part 8 for details.
3. If the existing motor is replaced with the HG-JR11K1M motor or JR15K1M motor, the replacement motor will not have a
cooling fan and thermal terminal block. Because the existing wiring becomes unnecessary, insulate the cables as needed.
4. Laying a new encoder cable is required when performing a replacement of a following motor. Contact a Mitsubishi Electric
System & Service Co., Ltd. if a new cable required.
• HG-JR22K1M(4)
• HG-JR15K1(4)
• HG-JR30K1M(4)
• HG-JR20K1(4)
• HG-JR37K1M(4)
• HG-JR25K1(4)
• HG-JR45K1M4
• HG-JR30K1(4)
• HG-JR55K1M4
• HG-JR37K1(4)
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...