Part 7: Common Reference Material
7 - 61
MR-J2S-_A_ MR-J4-_A_
Conversion rule
No.
Name
Type Target No. Type Target
49
Output signal selection 1
Hex
_ X_ _
PD28
Hex
_ _ XX
BWNG (battery warning) signal assignment will
be converted.
(1) When the setting value of No. 49 is _ 1 _ _
(CN1A-19), the setting value of PD28 will be
converted to _ _ 09 (CN1-49 pin setting).
(2) Only when the setting value of No. 1 is _ 0 _
_ (CN1B-18 is the initial value ALM), this
parameter will be converted.
When the setting value of No. 49 is _ 2 _ _
(CN1B-18), the setting value of PD27 will be
converted to _ _ 09.
(3) When the setting value of No. 49 is _ 3 _ _
(CN1A-18), the setting value of PD23 will be
converted to _ _ 09 (CN1-22 pin setting).
(4) Only when the setting value of No. 1 is _ _ 0
_ (CN1B-19 is the initial value ZSP), this
parameter will be converted.
When the setting value of No. 49 is _ 4 _ _
(CN1B-19), the setting value of PD24 will be
converted to _ _ 09 (CN1-23 pin setting).
(5) When the setting value of No. 49 is _ 5 _ _
(CN1B-6), the setting value of PD26 will be
converted to _ _ 09 (CN1-25 pin setting).
Otherwise, the initial value will be set.
When conversion of I/O signal assignment is
enabled, these parameters will be converted
according to the control signal connection of
the renewal tool.
When conversion of I/O signal assignment is
not enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or
later.
PD23
Hex
_ _ XX
PD24
Hex
_ _ XX
PD27
Hex
_ _ XX
PD26
Hex
_ _ XX
Hex
_ _ X _
PD28
Hex
_ _ XX
WNG (warning) signal assignment will be
converted.
(1) When the setting value of No. 49 is _ _ 1 _
(CN1A-19), the setting value of PD28 will be
converted to _ _ 08 (CN1-49 pin setting).
(2) Only when the setting value of No. 1 is _ 0 _
_ (CN1B-18 is the initial value ALM), this
parameter will be converted.
When the setting value of No. 49 is _ _ 2 _
(CN1B-18), the setting value of PD27 will be
converted to _ _ 08.
(3) When the setting value of No. 49 is _ _ 3 _
(CN1A-18), the setting value of PD23 will be
converted to _ _ 08 (CN1-22 pin setting).
(4) Only when the setting value of No. 1 is _ _ 0
_ (CN1B-19 is the initial value ZSP), this
parameter will be converted.
When the setting value of No. 49 is _ _ 4 _
(CN1B-19), the setting value of PD24 will be
converted to _ _ 08 (CN1-23 pin setting).
(5) When the setting value of No. 49 is _ _ 5 _
(CN1B-6), the setting value of PD26 will be
converted to _ _ 08 (CN1-25 pin setting).
Otherwise, the initial value will be set.
When conversion of I/O signal assignment is
enabled, these parameters will be converted
according to the control signal connection of
the renewal tool.
When conversion of I/O signal assignment is
not enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or
later.
PD23
Hex
_ _ XX
PD24
Hex
_ _ XX
PD27
Hex
_ _ XX
PD26
Hex
_ _ XX
Hex
_ _ _X
-
-
-
The setting value will not be maintained.
(Alarm code output setting)
Hex: hexadecimal parameter; Dec: decimal parameter
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...