Part 7: Common Reference Material
7 - 51
(6) Conversion rules (MR-J2S-_A_ => MR-J4-_A_)
The following table shows the parameter conversion rules from MR-J2S-_A_ to MR-J4-_A_.
Parameters not specified in the following table will be set to their initial values.
MR-J2S-_A_ MR-J4-_A_
Conversion rule
No.
Name
Type Target No. Type Target
0
Control mode and regenerative
option selection
Hex
_ _ _ X PA01
Hex
_ _ _ X The setting value will be maintained.
XX_ _
PA02
Hex
_ _ XX
00_ _ will be changed to _ _ 00.
01_ _ will be changed to _ _ 01.
02_ _ will be changed to _ _ 02.
03_ _ will be changed to _ _ 03.
04_ _ will be changed to _ _ 04.
05_ _ will be changed to _ _ 05.
06_ _ will be changed to _ _ 06.
08_ _ will be changed to _ _ 08.
09_ _ will be changed to _ _ 09.
0E_ _ will be changed to _ _ FA.
82_ _ will be changed to _ _ 82.
83_ _ will be changed to _ _ 83.
84_ _ will be changed to _ _84.
85_ _ will be changed to _ _85.
87_ _ will be changed to _ _81.
Otherwise, _ _ 00 will be set.
1
Function selection 1
Hex
X_ _ _
PA03
Hex
_ _ _ X
0_ _ _ will be changed to _ _ _ 0.
1_ _ _ will be changed to _ _ _ 1.
Otherwise, _ _ _0 will be set.
_ X _ _ PD27
Hex
_ _ XX
_0_ _ will be changed to _ _03.
_1_ _ will be changed to _ _06.
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _ X _ PD24
Hex
_ _ XX
_ _0_ will be changed to _ _0C. (ZSP)
_ _1_ will be changed to _ _05. (MBR)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _ _ X PD29
Hex
_ _ _ X
_ _ _ 1 will be changed to _ _ _ 2.
_ _ _ 2 will be changed to _ _ _ 4.
_ _ _ 3 will be changed to _ _ _ 4.
Otherwise, the setting value will be maintained.
Hex: hexadecimal parameter; Dec: decimal parameter
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...