Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 16
(b) When continuing to use the HC-_FS/HA-_FS motor:
Parameter
number
Name
Initial
value
Setting
value
Description
PA04
Function selection A-1
2 0 0 0h 0 0 0 0h Forced stop deceleration function selection
To configure the same settings as for MR-J2S-_CP_/MR-J2S-
_CL_, select "Forced stop deceleration function disabled (EM1)".
PA06
Electronic gear numerator
(Commanded pulse
multiplication numerator)
1 8
(Note)
When using an electronic gear, it is necessary to change the
setting value.
Set the electronic gear ratio of an existing servo amplifier.
When a geared servo motor is replaced, the actual reduction
ratio may differ before and after the replacement. If the ratio
differs after the replacement, set the values considering the
actual reduction ratio.
PA07
Electronic gear denominator
(Commanded pulse
multiplication denominator)
1 1
(Note)
PA21
Function selection A-3
0 0 0 1h 0 0 0 1h Electronic gear selection
Use with the initial value as is.
PA09
Auto tuning response
16
8
Auto tuning response setting
Enter this setting value for replacement, referring to "3.6.3
Comparison of parameter details".
It is necessary to make gain adjustment again when replacing.
For details about gain adjustment, refer to "MR-J2S-_CP_ [Pr. 3]
(MR-J4-_A_ [Pr. PA09])" in Section 3.6.3.
PD30
Function selection D-1
0 0 0 0h 1 _ _ _h This is used to select enabled or disabled for the thermistor of
the servo motor.
: When using (HA-LFS series) servo motors that have thermal
terminals and not connecting thermal signals to the MR-J4
servo amplifier, set this parameter to "1 _ _ _h (Disabled)".
The overheat protection of a servo motor is not enabled.
Configure a protective circuit.
Note. The example value shown is for when the electronic gear ratio of an existing servo amplifier is set as "8/1".
(2) When replacing MR-J2S-_CP_
Parameter
number
Name
Initial
value
Setting
value
Description
PA01
Operation mode
1 0 0 0h _ _ _ 6h Select the servo amplifier control mode.
Select the positioning mode (point table method).
(3) When replacing MR-J2S-_CL_
Parameter
number
Name
Initial
value
Setting
value
Description
PA01
Operation mode
1 0 0 0h _ _ _ 7h Select the servo amplifier control mode.
Select the positioning mode (program method).
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...