Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 46
(9) Data for test operation mode (command [9] [2]/[A] [0])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[9] [2]
[0] [0]
Input Signal During Test
Operation
Refer to "MR-J2S-
_CP Servo
Amplifier
Instruction Manual"
Section 15.12.7.
Input Signal During Test
Operation
Refer to "MR-J4-
_A_(-RJ) Servo
Amplifier Instruction
Manual" Section
14.5.7.
8
[A][0]
Signal Pin Forced Output Refer to "MR-J2S-
_CP Servo
Amplifier
Instruction Manual"
Section 15.12.9.
Signal Pin Forced Output Refer to "MR-J4-
_A_(-RJ) Servo
Amplifier Instruction
Manual" Section
14.5.9.
8
[A] [0]
[1] [0]
Write the speed in the test
operation mode (JOG
operation/positioning
operation).
0000-7FFF
Write the speed in the
test operation mode (JOG
operation/positioning
operation).
0000-7FFF 4
[1] [1]
Write the
acceleration/deceleration
time constants in the test
operation mode (JOG
operation/positioning
operation).
00000000 to
7FFFFFFF
Write the
acceleration/deceleration
time constants in the test
operation mode (JOG
operation/positioning
operation).
00000000 to
7FFFFFFF
8
[1] [2]
Cancel the
acceleration/deceleration
time constants in the test
operation mode (JOG
operation/positioning
operation).
1EA5
4
[1] [3]
Write the pulse travel
distance in the test
operation mode
(positioning operation).
80000000 to
7FFFFFFF
Refer to Data No. [2] [0]
and [2] [1].
8
[1] [5]
Temporary stop command
for the test operation
mode (positioning
operation).
1EA5
Refer to Data No. [4] [1].
4
[2] [0]
Set the travel distance
in the test operation
mode (positioning
operation).
00000000 to
7FFFFFFF
8
[2] [1]
Select the positioning
direction of the test
operation (positioning
operation).
0000 to 0001
4
[4] [0]
The start command for
the test operation
(positioning operation).
1EA5 4
[4] [1]
Use to stop the test
drive (positioning
operation) temporarily.
Symbols "
_
" below
indicate blanks.
STOP: Temporary stop
GO
__
: Restarting the
remaining distance
CLR
_
: Clearing the
remaining distance
STOP
GO
__
CLR
_
4
(10) Group setting (command [9] [F])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[9] [F]
[0] [0]
Set groups
a to f
Set groups
a to f
4
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...