[Appendix 1] Summary of MR-J4_B_-RJ020 + MR-J4-T20
Appendix 1-64
(3) MR-J4-11KB-RJ020 to MR-J4-22KB-RJ020 and MR-J4-11KB4-RJ020 to MR-J4-22KB4-RJ020 (when
the regenerative resistor that comes standard with the servo amplifier is used.)
Note
Since the regenerative resistor that comes with the servo amplifier of 11 kW to 22
kW has no protective cover, be careful of the following items.
• The surface of the part is a resistor and it becomes very hot. Touching it could cause
burns.
• The capacitor of the servo amplifier is charged for a while even after power is
disconnected. Touching it may cause electric shock.
When you use regenerative resistors that come standard with the servo amplifier, be sure to connect the
specified number (4 or 5 pcs.) in series. Parallel connection or use of regenerative resistors less than
the specified number could failure of the servo amplifier and/or burnout of regenerative resistors.
When regenerative resistors are installed side-by-side, keep a distance of 70 mm or more between
resistors. Cooling the resistors with cooling fans (1.0
㎥
/min or more, 92 mm square x 2 pcs.) enhances
regenerative power. In this case, set [Pr. 2] to "_ _ 0 E".
Note. The number of series connections varies depending on the type of resistors. Thermal
sensors are not built into the supplied regenerative resistors. In the case of a failure
of the regenerative circuit, the possible cause is abnormal overheating of resistors.
Therefore, you should install thermal sensors near resistors and install the protection
circuit that shuts off the main circuit power in the case of abnormal overheating. The
detection level of the thermal sensor varies depending on the method used for
installing resistors. Install thermal sensors in optimal locations according to your
design standard or use regenerative options with built-in thermal sensors (MR-RB5E,
MR-RB5R, MR-RB9P, MR-RB9F, MR-RB9T, MR-RB5K-4, MR-RB6B-4, MR-RB60-4
or MR-RB6K-4) .
Servo amplifier
Regenerative resistor
Regenerative power [W]
Resistance
value
[
Ω
]
Number
During normal
use
During cooling
MR-J4-11KB-RJ020
GRZG400-0.8
Ω
500 800 3.2
4
MR-J4-15KB-RJ020
GRZG400-0.6
Ω
850 1300
3
5
MR-J4-22KB-RJ020
GRZG400-0.5
Ω
2.5
MR-J4-11KB4-RJ020
GRZG400-2.5
Ω
500 800
10
4
MR-J4-15KB4-RJ020
MR-J4-22KB4-RJ020
GRZG400-2
Ω
850 1300 10
5
5 m or less
Servo
amplifier
(Note) Series
connection
Cooling fan
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...