Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 31
MR-J2S-_CP_ or MR-J2S-_CL_
MR-J4-_A_-RJ
No.
Name and function
Initial value
No.
Name and function
Initial
value
CP CL
42
Home position return position data
Set the current position of the time when the home
position return is completed.
Setting range: -32768 to 32767
0
0
PT08
Home position return position data
Set the current position of the time when the
home position return is completed.
Note that the home position return position data
is changed if the following parameters are
changed. Perform the home position return
again.
•
"Position data unit" of [Pr. PT01]
•
"Feed length multiplication (STM)" of [Pr.
PT03]
•
"Home position return types" of [Pr. PT04]
Setting range: -32768 to 32767
0
43
Travel distance after proximity dog
Set the "travel distance after proximity dog" when the
count type returns to the home position.
Setting range: 0 to 65535
1000
1000
PT09
Travel distance after proximity dog
When the count type, dog type rear end
reference, count type front end reference and
dog type front end reference return to the home
position, set the "travel distance after proximity
dog".
Setting range: 0 to 65535
1000
44
Stopper type home position return - Stopper time
When the stopper type returns to the home position,
after pressing against the stopper, set the time between
when the parameter No.45 (ZTT) reaches the torque
limit and the time when setting the home position.
Setting range: 5 to 1000
100
100
PT10
Stopper type home position return - Stopper time
When the stopper type returns to the home
position, after pressing against the stopper, set
the time between when the [Pr. PT11 Stopper
type home position return torque limit value]
reaches the torque limit and the time when
setting the home position.
Setting the value between "0" and "4" will result
in the same value as the one with "5" set.
Setting range: 0 to 1000
100
45
Stopper type home position return torque limit value
Set the torque limit value of the time when the stopper
type returns to the home position by a ratio [%] to the
maximum torque.
Setting range: 1 to 100
15 15 PT11
Stopper type home position return torque limit
value
Set the torque limit value of the time when the
stopper type returns to the home position by a
ratio [%] to the maximum torque.
Setting "0.0" will result in the same value as the
one with "1.0" set.
Setting range: 0:0 to 100.0
15.0
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...