Part 6: Review on Replacement of MR-J2M with MR-J4
6 - 17
4.7 Comparison of Parameters
The correspondence of the MR-J2M series and MR-J4 series parameter numbers is shown below. Refer to
the respective Instruction Manuals for detailed specifications of each parameter.
4.7.1 Parameter comparison list
POINT
Parameters for manufacturer setting are not described here.
With MR-J4-_B_, the deceleration to a stop function is enabled in the factory
setting. To disable the deceleration to a stop function, set [Pr. PA04] to "0 _ _ _".
For details, refer to "Part 3: Review on Replacement of MR-J2S-_B_ with MR-
J4-_B_".
(1) Interface unit MR-J2M-P8A
MR-J2M-B
(Interface unit MR-J2M-P8B)
MR-J4-_B_
Note
No. Name No.
Name
0
Serial communication function selection
No serial communication function.
Alarm history clear
PC21 Alarm history clear
1
Serial communication time-out selection
No serial communication function.
2
Serial communication protocol checksum
selection
No serial communication function.
3
Analog monitor 1 output
PC09 Analog monitor 1 output
The setting value must be changed
according to monitor output data.
4
Analog monitor 2 output
PC10 Analog monitor 2 output
5
Analog monitor 3 output
6
Analog monitor output 1 offset
PC11 Analog monitor 1 offset
Depends on hardware.
Change the setting value.
7
Analog monitor output 2 offset
PC12 Analog monitor 2 offset
8
Analog monitor output 3 offset
9
SSCNET type selection
(SSCNET communication cycle)
MR-J4-_B_ is compatible with
SSCNET III/H only. The
communication cycle depends on
the specifications of the controller
and the number of connected axes.
10
Electromagnetic brake interlock (MBR) axis
No. selection
Assigned to CN3.13
Test operation selection
The test operation can be set with
the control axis setting switch
(SW2).
11
1st slot serial communication station number
selection
The axis No. can be set with the
selection rotary switch (SW1).
12
2nd slot serial communication station number
selection
13
3rd slot serial communication station number
selection
14
4th slot serial communication station number
selection
15
5th slot serial communication station number
selection
16
6th slot serial communication station number
selection
17
7th slot serial communication station number
selection
18
8th slot serial communication station number
selection
19 IFU parameter writing inhibit
PA19 Parameter
writing
inhibit
Change the setting value as
necessary.
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...