Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
5 - 27
(2) Drive unit
POINT
Manufacturer setting parameters are not described here.
(a) General-purpose interface 200 V class
Here are described settings of drive unit specific parameters. Settings of the other parameters are
the same as MR-J4-_A_. Refer to Chapter 5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction
Manual".
MR-J2S_A MR-J4_A
No.
Name and function
Initial
value
No.
Name and function
Initial
value
0
Control mode and regenerative option selection
0000h PA02 Regenerative
options
Select a regenerative option.
For a drive unit, select a regenerative option by
configuring the converter unit.
Select "_ _ 0 0" or "_ _ 0 1", otherwise [AL. 37 Parameter
error] will occur.
00:
Use no regenerative option, or use a regenerative
option by configuring the converter unit.
0000h
(b) SSCNET interface 200 V class
POINT
Connecting to a servo system controller results in servo parameters of the
controller written to the corresponding parameters of the drive unit.
Some servo system controller models, drive unit software versions, and MR
Configurator2 software versions limit setting of some parameters or setting
values of the parameters. For details, refer to servo system controller user's
manuals.
Here are described settings of drive unit specific parameters. Settings of the other parameters are
the same as MR-J4-_B_. Refer to Chapter 5 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction
Manual".
MR-J2S_B MR-J4_B
No.
Name and function
Initial
value
No.
Name and function
Initial
value
2 Regenerative
resistor
0000h PA02 Regenerative
options
Select a regenerative option.
For a drive unit, select a regenerative option by
configuring the converter unit.
Select "_ _ 0 0" or "_ _ 0 1", otherwise [AL. 37 Parameter
error] will occur.
00:
Use no regenerative option, or use a regenerative
option by configuring the converter unit.
0000h
0
0
Regenerative option selection
Make sure to set “00”.
Refer to the MR-J2S-_B_ servo amplifier
Instruction Manual.
0
0
0
0
0
Refer to the MR-J2S-_A_ servo amplifier
Instruction Manual.
Make sure to select regenerative option
selection “0”.
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...