Part 7: Common Reference Material
7 - 60
MR-J2S-_A_ MR-J4-_A_
Conversion rule
No.
Name
Type Target No. Type Target
48
Input signal selection 7
Hex
_ _ _ X
PD09 Hex
_ _ XX
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 5, this parameter will be converted.
The setting value will be converted as shown in
Table 1 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 1 (as input) in Section 2.3.5 (6) will be
converted to _ _05. (TL)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
_ _ X _
XX _ _
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 5, this parameter will be converted.
The setting value will be converted as shown in
Table 2 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 2 (as input) in Section 2.3.5 (6) will be
converted to 08_ _. (ST2)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
Hex
_ X _ _ PD10
Hex
_ _ XX
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 5, this parameter will be converted.
The setting value will be converted as shown in
Table 3 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 3 (as input) in Section 2.3.5 (6) will be
converted to _ _08. (RS1)
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
Hex: hexadecimal parameter; Dec: decimal parameter
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...