[Appendix 2] Introduction to Renewal Tool
Appendix 2-84
7. PARAMETER SETTING
7.1 List of General-Purpose Interface Setting Requisite Parameters
(1) For primary replacement
The following parameters are a minimum number of parameters that need to be set for primary
replacement. Depending on the settings of the currently used servo amplifier, parameters other than
these may need to be set. For details,
refer to Part 2 Section 3.6
.
Parameter
number
Setting item
Setting value
Description
Changing required.
PA04
Function selection A-1
0000h
Forced stop deceleration function selection
To configure the same settings as those for MR-J2S, select "Forced stop
deceleration function disabled (EM1)".
PC22
Function selection C-1
_ 1 _ _ h
Serial encoder selection.
This setting is for communication with the encoder of MR-J2S. An incorrect setting
causes encoder initial communication data error 1 (AL.20.1).
PA09
Auto Tuning Response
8
Auto tuning response setting
When replacing, switch the power on after setting the parameter value to "8".
*
It is necessary to make gain adjustment again when replacing.
The setting value of this parameter is equivalent to the slow response of the MR-
J2S. Perform adjustment since tha gain can be too low for the slow response.
For details on how to make gain adjustments, refer to Chapter 6 of the MR-J4
Servo Amplifier Instruction Manual
.
PD27
Output device selection 2
* 11 kW or more, only when
using this function
0006h
Dynamic brake interlock (DB) selection)
When using this function for the MR-J2S servo amplifier of 11 kW or more, set the
parameter. Assign a DB signal to pin CN1-48.
PD03 to PD14 Input signal device selection
-
When the assignment of the Input/output signal for the existing MR-J2S servo
amplifier is changed, setting is required.
For details, refer to Section 5.2 in "Manual for Replacement from MR-J2S Renewal
Tool (X903120707)" issued by Mitsubishi Electric System & Service Co., Ltd.
Position control mode only
PA06
Electronic gear numerator (CMX)
(Command input pulse
multiplication numerator)
8
(Note 1)
When using an electronic gear, it is necessary to change the setting value.
Set the same value as [Pr. 3] or [Pr. 4] of for the MR-J2S-_A_ servo amplifier.
PA07 Electronic
gear
denominator
(CDV)
(Commanded pulse
multiplication denominator)
1
(Note 1)
PA21
Electronic gear selection
0001h
A setting value for the electronic gear [Pr. PA06] or [Pr. PA07] becomes effective.
PA13
Command pulse input form
_ 2 _ _ h
Pulse train filter selection
The setting value mentioned at the left side is a command pulse train filter setting
equivalent to the MR-J2S-_A_ (when setting the differential line driver type).
* If it is not set, position mismatch will occur. Make sure to set a filter.
In addition, it is necessary to adjust the command pulse logic to the positioning
module. For details, refer to Part 2 Section 3.7.
* An incorrect logic setting causes the servo motor to not rotate. Make sure
to configure the settings.
PA10 In-position
range
100
(Note 2)
In-position range
Used to set an in-position range per command pulse unit.
Set the same value as [Pr. 5] of for the MR-J2S-_A_ servo amplifier.
Speed control mode only
PA01
Control mode
_ _ _ 2h
Select the servo amplifier control mode.
Select the speed control mode.
PC12
Analog speed command -
Maximum speed
3000
(Note 3)
Analog speed command - Maximum speed
Note 1. The example value shown is for when the electronic gear setting of an existing servo amplifier is set as "8/1".
2. The example value shown is for when the in-position range of an existing servo amplifier is set as "100".
3. The example value shown is for when the servo amplifier setting of an existing servo amplifier is set as "3000".
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...