Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 29
MR-J2S-_CP_ or MR-J2S-_CL_
MR-J4-_A_-RJ
No.
Name and function
Initial value
No.
Name and function
Initial
value
CP CL
30 Backlash
compensation
Set the backlash compensation that is compensated
when the command direction is reversed.
Compensate the number of backlash pulses reversely-
directed against the home position return direction.
In the absolute position detection system, compensation
is performed reversely against the operating direction
taken at power-on.
e: Depending on the software version of servo amplifier,
the setting range varies as follows:
] A4 version or later: 0 to 1600
A3 version or earlier: 0 to 1000
] A1 version or later: 0 to 1600
A0 version: 0 to 1000
0 0 PT14
Backlash
compensation
Set the backlash compensation that is
compensated when the command direction is
reversed.
Compensate the number of backlash pulses
reversely-directed against the home position
return direction.
In the case of home position ignorance (servo-on
position as home position), compensate the
number of backlash pulses reversely-directed
against the initial rotation after turning on the
SON (servo-on) to establish the home position.
Setting range: 0 to 65535
0
31
Analog monitor 1 offset
Used to set the offset voltage of Analog monitor 1 (MO1).
Setting range: -999 to 999 mV
0
0
PC39 Analog monitor 1 offset
Used to set the offset voltage of MO1 (Analog
monitor 1).
Setting range: -9999 to 9999 mV
0
32
Analog monitor 2 offset
Used to set the offset voltage of Analog monitor 2 (MO2).
Setting range: -999 to 999 mV
0
0
PC40 Analog monitor 2 offset
Used to set the offset voltage of MO2 (Analog
monitor 2).
Setting range: -9999 to 9999 mV
0
33
Electromagnetic brake sequence output
Used to set the delay time (Tb) between MBR
(Electromagnetic brake interlock) OFF and base circuit
shut-off.
Setting range: 0 to 1000 ms
100
100
PC16 Electromagnetic brake sequence output
Used to set the delay time (Tb) between MBR
(Electromagnetic brake interlock) OFF and base
circuit shut-off.
Setting range: 0 to 1000 ms
Set the same value as for MR-J2S-_CP_.
0
34
Load to motor inertia ratio
Used to set the motor inertia ratio to the servo motor
shaft inertia moment.
When auto tuning is selected, the auto tuning result is
automatically used.
Setting range: 0 to 1000; Unit: x1.0
70
70
PB06
Load to motor inertia ratio
When auto tuning mode 1 is selected, the auto
tuning result is automatically used.
Setting range: 0.00 to 300.00; Unit: x1.0
Note that the setting unit is different from that for
MR-J2S-_CP_.
When setting a value manually, set a value 0.1 x
the MR-J2S-_CP_ setting value.
7.00
35
Position loop gain 2
Used to set the gain of the position loop.
Set this parameter to increase the position response to
level load disturbance.
Higher setting increases the response level but is liable
to generate vibration and/or noise.
When auto tuning is selected, the auto tuning result is
automatically used.
35
35
PB08
Position loop gain
Used to set the gain of the position loop.
When auto tuning mode 1 is selected, the auto
tuning result is automatically used.
37.0
36
Speed loop gain 1
Normally, it is unnecessary to change this parameter.
Higher setting increases the response level but is liable
to generate vibration and/or noise.
When auto tuning is selected, the auto tuning result is
automatically used.
177 177
No
corresponding
parameter
This parameter is automatically set by the servo
amplifier.
37
Speed loop gain 2
Set this parameter when vibration occurs on machines of
low rigidity or large backlash.
Higher setting increases the response level but is liable
to generate vibration and/or noise.
When auto tuning is selected, the auto tuning result is
automatically used.
817 817 PB09
Speed
loop
gain
Used to set the gain of the speed loop.
When auto tuning mode 1 is selected, the auto
tuning result is automatically used.
823
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...