Part 7: Common Reference Material
7 - 97
4. HC-_FS /HA-_FS MOTOR DRIVE
4.1 Parameter setting
(1) MR-J4-_A_
When driving the HC-_FS /HA-_FS series servo motor with MR-J4-_A_, configure [Pr. PC22] at "_ 1 _ _"
and select the encoder setting compatible with MR-J2S. If there is an error in the setting, [AL.16:
Encoder initial communication error 1] or [AL.20: Encoder normal communication error 1] occurs.
No./symbol/name
Setting
digit
Function
Initial value
[unit]
PC22
**COP1
Function
selection C-1
_ _ _ x For manufacturer setting
0h
_ _ x _
0h
_ x _ _ Encoder setting selection
0: MR-J4 compatible encoder setting
1: MR-J2S compatible encoder setting
If there is an error in the setting, [AL.16: Encoder initial communication error 1] or
[AL.20: Encoder normal communication error 1] occurs.
0h
x _ _ _ Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
If there is an error in the setting, [AL.16: Encoder initial communication error 1] or
[AL.20: Encoder normal communication error 1] occurs.
0h
(2) MR-J4-_B_
When driving the HC/HA series servo motor with MR-J4-_B_, configure [Pr. PC04] at "_ 1 _ _" and select
a compatible encoder setting with MR-J2S. If there is an error in the setting, [AL.16: Encoder initial
communication error 1] or [AL.20: Encoder normal communication error 1] occurs.
No./symbol/name
Setting
digit
Function
Initial value
[unit]
PC04
**COP1
Function
selection C-1
_ _ _ x For manufacturer setting
0h
_ _ x _
0h
_ x _ _ Encoder setting selection
0: MR-J4 compatible encoder setting
1: MR-J2S compatible encoder setting
If there is an error in the setting, [AL.16: Encoder initial communication error 1] or
[AL.20: Encoder normal communication error 1] occurs.
0h
x _ _ _ Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
If there is an error in the setting, [AL.16: Encoder initial communication error 1] or
[AL.20: Encoder normal communication error 1] occurs.
0h
POINT
When using HC/HA series servo motors without being replaced, check and change
the "electronic gear setting" and "pulse output".
For MR-J4-_A_, refer to Section 2.3.5 (5). For MR-J4-_B_, refer to Section 2.4.3 (2).
Refer to "Appendix 1. 13 OPTIONS AND PERIPHERAL EQUIPMENT" for
"connected cables" when using the HC/HA series servo motors without replacing.
When driving the HC-_FS/HA-_FS series servo motors with the MR-J4-_A_/MR-J4-
_B_, use regenerative options that are to be used for the MR-J4 series servo
amplifiers.
For details regarding combinations of servo amplifiers and regenerative options,
refer to "1. COMPARISON TABLE OF REGENERATIVE OPTION
COMBINATIONS" of "Part 9: Review on Replacement of Optional Peripheral
Equipment".
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...