Part 7: Common Reference Material
7 - 91
MR-J2S-_B_ MR-J4-_B_
Conversion rules
No.
Name
Type Target No. Type Target
18
Machine resonance suppression
filter 1
(Notch filter)
Hex
_ _ XX PB01
Hex
_ _ _ X
_ _ 00 will be changed to _ _ _ 0.
Otherwise, _ _ _ 2 will be set.
_ _ XX PB13
Dec
-
_ _ 00 will be changed to 4500.
_ _ 01 will be changed to 4500.
_ _ 02 will be changed to 2250.
_ _ 03 will be changed to 1500.
_ _ 04 will be changed to 1125.
_ _ 05 will be changed to 900.
_ _ 06 will be changed to 750.
_ _ 07 will be changed to 643.
_ _ 08 will be changed to 563.
_ _ 09 will be changed to 500.
_ _ 0A will be changed to 450.
_ _ 0B will be changed to 409.
_ _ 0C will be changed to 375.
_ _ 0D will be changed to 346.
_ _ 0E will be changed to 321.
_ _ 0F will be changed to 300.
_ _ 10 will be changed to 281.
_ _ 11 will be changed to 265.
_ _ 12 will be changed to 250.
_ _ 13 will be changed to 237.
_ _ 14 will be changed to 225.
_ _ 15 will be changed to 214.
_ _ 16 will be changed to 205.
_ _ 17 will be changed to 196.
_ _ 18 will be changed to 188.
_ _ 19 will be changed to 180.
_ _ 1A will be changed to 173.
_ _ 1B will be changed to 167.
_ _ 1C will be changed to 160.
_ _ 1D will be changed to 155.
_ _ 1E will be changed to 150.
_ _ 1F will be changed to 145.
_ X_ _
PB14
Hex
_ _ X_ The setting value will be maintained.
19 Feed forward gain
Dec
-
PB04
Dec
-
The setting value will be maintained.
20
In-position
range
Dec - PA10
Dec -
When the setting value of No. 6 is 0, the setting
value of No. 20 will be multiplied by 16.
When the setting value of No. 6 is 1, the setting
value of No. 20 will be multiplied by 32.
When the setting value of No. 6 is 6, the setting
value of No. 20 will be multiplied by 8.
When the setting value of No. 6 is 7 or 255, the
setting value of No. 20 will be doubled.
When the above value is 4095 or smaller, the
value will be multiplied by 16.
When the above value is 4096 or larger, 65535
will be set.
To use the HC/HA series servo motors without
being replaced, refer to (2) in Section 2.4.3.
21
Electromagnetic brake
sequence output
Dec
-
PC02
Dec
-
The setting value will be maintained.
Hex: hexadecimal parameter; Dec: decimal parameter
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...