(a) When using the HA-_FS/HC-_FS motors (J2S compatibility mode)
List of regenerative options
Servo amplifier
model
Built-in
regenerative
resistor
[W]
Permissible regenerative power of regenerative option [W] MR-RB
1H-4
[82
Ω
]
1L-4
[270
Ω
]
(Note 1)
3M-4
[120
Ω
]
(Note 1)
3H-4
[80
Ω
]
(Note 1)
3G-4
[47
Ω
]
(Note 1)
34-4
[26
Ω
]
(Note 1)
3U-4
[22
Ω
]
(Note 1)
5H-4
[80
Ω
]
(Note 1)
5G-4
[47
Ω
]
(Note 1)
54-4
[26
Ω
]
(Note 1)
5U-4
[22
Ω
]
MR-J4-60B4-RJ020
15
(Note
4)
100
100
300
MR-J4-100B4-RJ020
15
(Note
4)
100
300
MR-J4-200B4-RJ020 100
300
500
MR-J4-350B4-RJ020 100 300 500
MR-J4-500B4-RJ020 130 300 500
MR-J4-700B4-RJ020 170
300
500
MR-J4-11KB4-RJ020
MR-J4-15KB4-RJ020
MR-J4-22KB4-RJ020
MR-J4-DU30KB4-RJ020
MR-J4-DU37KB4-RJ020
MR-J4-DU45KB4-RJ020
MR-J4-DU55KB4-RJ020
Servo amplifier
model
Built-in
regenerative
resistor
[W]
(Note 2)
MR-J2S standard
accessories
[External]
Permissible regenerative power of regenerative option [W] MR-RB
(Note 2)
5K-4
[10
Ω
]
(Note 2)
6B-4
[20
Ω
]
(Note 2)
60-4
[12.5
Ω
]
(Note 2)
6K-4
[10
Ω
]
136-4
[5
Ω
]
(Note 3)
138-4
[5
Ω
]
MR-J4-60B4-RJ020
15
(Note
4)
MR-J4-100B4-RJ020
15
(Note
4)
MR-J4-200B4-RJ020
100
MR-J4-350B4-RJ020
100
MR-J4-500B4-RJ020
130
MR-J4-700B4-RJ020
170
MR-J4-11KB4-RJ020
GRZG400-5
Ω
× 4
500 (800)
500
(800)
MR-J4-15KB4-RJ020
GRZG400-2.5
Ω
× 5
850 (1300)
850
(1300)
MR-J4-22KB4-RJ020
GRZG400-2
Ω
× 5
850 (1300)
850
(1300)
MR-J4-DU30KB4-RJ020
1300
3900
MR-J4-DU37KB4-RJ020
1300
3900
MR-J4-DU45KB4-RJ020
1300
3900
MR-J4-DU55KB4-RJ020
1300
3900
Note 1. Always install a cooling fan.
2. The values in the parentheses are applied to when a cooling fan is installed.
3. The value of MR-RB138-4 is the combined resistance of three units.
4. The capacity of the built-in regenerative resistor is small for the MR-J2S servo amplifier.
Consider based on regenerative load ratio.
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...