Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 47
[Communication command comparison between MR-J2S-_CL _ series and MR-J4-_A_-RJ series]
Table 4.3 compares the read commands between the MR-J2S-_CL_series and MR-J4-_A_-RJ series ([Pr.
PT01]: when setting "3 _ _ _"), and table 4.4 compares the write commands. The functions added in the MR-
J4-_A_-RJ series are not included here. For details, refer to "MR-J4-_A_(-RJ) Servo Amplifier Instruction
Manual (SH(NA)030143))".
POINT
[Pr. PT01]: MR Configurator2 cannot be used when the parameter is set to "3 _
_ _".
[Table 4.3] Compares the read commands between MR-J2S-_CL_and MR-J4-_A_-RJ ([Pr. PT01]: when
setting "3 _ _ _").
(1) Status Display (command [0] [1])
Command Data
No.
Description
Displayed items
Frame
length
MR-J2S-_CL_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "3 _ _ _"
[0] [1]
[8] [0]
Data value of status
display and processed
information
Current position
Current position
12
[8] [1]
Command position
Command position
[8] [2]
Command remaining distance
Command remaining distance
[8] [3]
Program No.
Program No.
[8] [4]
Step No.
Step No.
[8] [5]
Cumulative Feedback Pulses
Cumulative Feedback Pulses
[8] [6]
Servo motor speed
Servo motor speed
[8] [7]
Droop pulses
Droop pulses
[8] [8]
Override
Override
[8] [9]
Torque limit voltage
Torque limit voltage
[8] [A]
Regenerative load ratio
Regenerative load ratio
[8] [B]
Effective load ratio
Effective load ratio
[8] [C]
Peak load ratio
Peak load ratio
[8] [D]
Instantaneous torque
Instantaneous torque
[8] [E]
Within one-revolution position
Within one-revolution position
[8] [F]
ABS counter
ABS counter
[9] [0]
Load to inertia moment ratio
Load to inertia moment ratio
[9] [1]
Bus voltage
Bus voltage
(2) Parameter (command [0] [5])
Command Data
No.
Description
Frame
length
MR-J2S-_CL_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "3 _ _ _"
[0] [5]
[0] [0]
to
[5] [A]
Current values of each parameter
The data number converted from hexadecimal
to decimal corresponds to the parameter No.
Current values of each parameter
Read the current parameter in the
parameter group specified by the command
[8] [5] + data No. [0] [0]. Thus, make sure to
specify the parameter group by the
command [8] [5] + data No. [0][0] before
reading the current value.
The data number
converted from hexadecimal to decimal
corresponds to the parameter No.
8
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...