Part 7: Common Reference Material
7 - 54
MR-J2S-_A_ MR-J4-_A_
Conversion rule
No.
Name
Type Target No. Type Target
41
Input signal automatic ON
selection
Hex
_ _ _ X PD01
Hex
_ _ _ X
_ _ _ 0 will be changed to _ _ _ 0.
_ _ _ 1 will be changed to _ _ _ 4.
Otherwise, the initial value will be set.
_ XX_
PD01
Hex
_ X_ _
_ 00_ will be changed to _ 0 _ _.
_ 01_ will be changed to _ 4 _ _.
_ 10_ will be changed to _ 8 _ _.
_ 11_ will be changed to _ C _ _.
Otherwise, the initial value will be set.
42
Input signal selection 1
Hex
_ _ X_ PD32
Hex
_ _ _ X The setting value will be maintained.
_ _ _ X
PD03 Hex XXXX
(1) Only when the setting value of No. 0 is _ _ _
1, _ _ _ 3, or _ _ _ 5, this parameter will be
converted as follows:
(LOP signal)
(1-1) When the setting value of No. 42 is _ _ _ 0
(CN1B-5)
PD03: 2323
PD04: _ _23 (CN1-15 pin setting)
(1-2) When the setting value of No. 42 is _ _ _ 1
(CN1B-14)
PD11: 2323
PD12: _ _23 (CN1-19 pin setting)
(1-3) When the setting value of No. 42 is _ _ _ 2
(CN1A-8)
PD13: 2323
PD14: _ _23 (CN1-41 pin setting)
(1-4) When the setting value of No. 42 is _ _ _ 3
(CN1B-7)
PD05: 2323
PD06: _ _23 (CN1-16 pin setting)
(1-5) When the setting value of No. 42 is _ _ _ 4
(CN1B-8)
PD07: 2323
PD08: _ _23 (CN1-17 pin setting)
(1-6) When the setting value of No. 42 is _ _ _ 5
(CN1B-9)
PD09: 2323
PD10: _ _23 (CN1-18 pin setting)
When conversion of I/O signal assignment is
enabled, these parameters will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
PD04
Hex
_ _ XX
PD11 Hex XXXX
PD12
Hex
_ _ XX
PD13 Hex XXXX
PD14
Hex
_ _ XX
PD05 Hex XXXX
PD06
Hex
_ _ XX
PD07 Hex XXXX
PD08
Hex
_ _ XX
PD09 Hex XXXX
PD10
Hex
_ _ XX
Hex: hexadecimal parameter; Dec: decimal parameter
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...