[Appendix 2] Introduction to Renewal Tool
Appendix 2-64
(4) Existing HA-LFS motor series
○
: Compatible;
△
: Limited functions or compatible with certain conditions;
×
: Incompatible
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Existing model
(Note 13)
Primary replacement model
(Note 5)
Secondary replacement/simultaneous replacement models
Servo
amplifier
model
Servo
motor
model
Servo
amplifier
model
(Note 1, 12)
SSCNET
conversion
unit model
(Note 1)
Renewal kit
model
Servo
amplifier
model
(Note 1)
SSCNET
conversion
unit model
(Note 1)
Servo
motor
model
(Note 1)
Renewal kit
model
Motor side conversion cable model
Compatibility
Power supply
conversion Cable
Encoder
Conversion cable
Brake/Conversion
cable for the
cooling fan
[Medium/large capacity/low inertia HA-LFS 1000 r/min series, standard/with brake] ((B) represents models with brake)
MR-
J2S-
700B4
HA-
LFS6014(B)
(Note 16)
MR-J4-
700B4-
RJ020
MR-J4-
T20
HG-
JR6014(B)
(Note 4)
×
(Note 3)
SC-J2SJ4BS05
(Note 18)
SC-
J2SJ4PW3C1M
-
■
Existing cable
can be used
• Existing
brake
cable can
be used.
• Cooling
fan cable
(Note 9)
MR-
J2S-
11KB4
HA-
LFS8014(B)
MR-J4-
11KB4-
RJ020
HG-
JR8014(B)
(Note 4)
SC-J2SJ4BS06
(Note 18)
HA-
LFS12K14(B)
HG-
JR12K14(B)
(Note 4)
MR-
J2S-
15KB4
HA-
LFS15K14
MR-J4-
15KB4-
RJ020
HG-
JR15K14
(Note 8)
(Note 17)
• Cooling
fan
conversion
cable
SC-
J2SJ4FAN1C1M
MR-
J2S-
22KB4
HA-
LFS20K14
MR-J4-
22KB4-
RJ020
HG-
JR20K14
SC-J2SJ4BS07
(Note 18)
MR-
J2S-
30KB4
HA-
LFS25K14
HG-
JR25K14
(Note 11)
HA-
LFS30K14
MR-J4-
DU30KB4-
RJ020
(Note 21)
HG-
JR30K14
(Note 4)
SC-J2SJ4BS08
(Note 18)
MR-
J2S-
37KB4
HA-
LFS37K14
MR-J4-
DU37KB4-
RJ020
(Note 21)
HG-
JR37K14
SC-J2SJ4BS09
(Note 18)
[Medium/large capacity/low inertia HA-LFS 1500 r/min series, standard/with brake] ((B) represents models with brake)
MR-
J2S-
700B4
HA-
LFS701M4(B)
(Note 16)
MR-J4-
700B4-
RJ020
MR-J4-
T20
HG-
JR701M4(B)
(Note 4)
×
(Note 3)
SC-J2SJ4BS05
(Note 18)
SC-
J2SJ4PW3C1M
-
■
Existing cable
can be used
• Existing
brake
cable can
be used.
• Cooling
fan cable
(Note 9)
MR-
J2S-
11KB4
HA-
LFS11K1M4
(B)
MR-J4-
11KB4-
RJ020
HG-
JR11K1M4
(B)
SC-J2SJ4BS06
(Note 18)
MR-
J2S-
15KB4
HA-
LFS15K1M4
(B)
MR-J4-
15KB4-
RJ020
HG-
JR15K1M4
(B)
(Note 4)
MR-
J2S-
22KB4
HA-
LFS22K1M4
MR-J4-
22KB4-
RJ020
HG-
JR22K1M4
SC-J2SJ4BS07
(Note 18)
(Note 8)
(Note 17)
• Cooling
fan
conversion
cable
SC-
J2SJ4FAN1C1M
MR-
J2S-
30KB4
HA-
LFS30K1M4
MR-J4-
DU30KB4-
RJ020
(Note 21)
HG-
JR30K1M4
SC-J2SJ4BS08
(Note 18)
MR-
J2S-
37KB4
HA-
LFS37K1M4
MR-J4-
DU37KB4-
RJ020
(Note 21)
HG-
JR37K1M4
SC-J2SJ4BS09
(Note 18)
MR-
J2S-
45KB4
HA-
LFS45K1M4
MR-J4-
DU45KB4-
RJ020
(Note 21)
HG-
JR45K1M4
MR-
J2S-
55KB4
HA-
LFS50K1M4
MR-J4-
DU55KB4-
RJ020
(Note 21)
HG-
JR55K1M4
[Medium/large capacity/low inertia HA-LFS 2000 r/min series, standard/with brake] ((B) represents models with brake)
MR-
J2S-
11KB4
HA-
LFS11K24(B)
MR-J4-11KB4-
RJ020
MR-J4-
T20
SC-
J2SJ4BS06
(Note 18)
MR-J4-
11KB4-
RJ020
MR-J4-
T20
HG-
JR11K1M4
(B)
(Note 4)
×
(Note 3)
SC-J2SJ4BS06
(Note 18)
SC-
J2SJ4PW3C1M
-
■
Existing cable
can be used
• Existing
brake
cable can
be used.
• Cooling
fan cable
(Note 9)
MR-
J2S-
15KB4
HA-
LFS15K24(B)
MR-J4-15KB4-
RJ020
(Note 10)
SC-
J2SJ4BS06
(Note 18)
MR-J4-
11KB4-
RJ020
(Note 10)
HG-
JR11K1M4
(B)
MR-
J2S-
22KB4
HA-
LFS22K24(B)
MR-J4-22KB4-
RJ020
(Note 10)
SC-
J2SJ4BS07
(Note 18)
MR-J4-
15KB4-
RJ020
(Note 10)
HG-
JR15K1M4
(B)
(Note 11)
MR-
J2S-
30KB4
HA-
LFS30K24
MR-J4-
DU30KB4-
RJ020
(Note 10, 21)
SC-
J2SJ4BS08
(Note 18)
MR-J4-
22KB4-
RJ020
(Note 10)
HG-
JR22K1M4
(Note 8)
(Note 17)
• Cooling
fan
conversion
cable
SC-
J2SJ4FAN1C1M
MR-
J2S-
37KB4
HA-
LFS37K24
MR-J4-
DU37KB4-
RJ020
(Note 10, 21)
SC-
J2SJ4BS09
(Note 18)
MR-J4-
DU30KB4-
RJ020
(Note 10, 21)
HG-
JR30K1M4
SC-J2SJ4BS09
(Note 18)
MR-
J2S-
45KB4
HA-
LFS45K24
MR-J4-
DU45KB4-
RJ020
(Note 10, 21)
MR-J4-
DU37KB4-
RJ020
(Note 10, 21)
HG-
JR37K1M4
MR-
J2S-
55KB4
HA-
LFS55K24
MR-J4-
DU55KB4-
RJ020
(Note 10, 21)
MR-J4-
DU45KB4-
RJ020
(Note 10, 21)
HG-
JR45K1M4
Refer to Appendix page 2-65 for important points to note.
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...