Part 4: Review on Replacement of MR-J2S-_CP_/CL_ with MR-J4-_A_-RJ
4 - 43
[Table 4.2] Compares the write commands between MR-J2S-_CP_ and MR-J4-_A_-RJ ([Pr. PT01]: when
setting "2 _ _ _").
(1) Status Display (command [8] [1])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[8] [1]
[0] [0]
Erasing the status
display data
1EA5
Erasing the status
display data
1EA5
4
(2) Parameter (command [8] [4])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[8] [4]
[0] [0]
to
[5] [A]
(Note)
Writing each parameter
The data number
converted from
hexadecimal to decimal
corresponds to the
parameter No.
Varies with the
parameter.
Writing each parameter
Write the parameter in
the parameter group
specified by the
command [85] + data
No. [00]. Thus, make
sure to specify the
parameter group by the
command [85] + data
No. [00] before writing
the value.
The data
number converted from
hexadecimal to decimal
corresponds to the
parameter No.
Varies with the
parameter.
8
Note. MR-J4-_A_-RJ will be in the range between [0] [1] and [F] [F].
(3) External I/O signal (command [9] [2])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[9] [2]
[6] [0]
Communication input
device signal
Refer to "MR-J2S-
_CP Servo
Amplifier
Instruction
Manual" Section
15.12.5.
Communication input
device signal
Refer to "MR-J4-
_A_(-RJ) Servo
Amplifier
Instruction Manual"
Section 10.2.2.
8
(4) Alarm history (command [8] [2])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[8] [2]
[2] [0]
Alarm History Clearing
1EA5
Alarm History Clearing
1EA5
4
(5) Current alarm (command [8] [2])
Command Data
No.
MR-J2S-_CP_
MR-J4-_A_-RJ
[Pr. PT01]: when setting "2 _ _ _"
Frame
length
Description
Setting range
Description
Setting range
[8] [2]
[0] [0]
Clearing alarms
1EA5 Clearing
alarms
1EA5
4
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...