Part 9: Review on Replacement of Optional Peripheral Equipment
9 - 49
8. SETUP SOFTWARE
8.1 MR-J2S Series Setup Software
Setup software (MRZJW3-SETUP161E) uses the communication function of the servo amplifier to change
parameter setting values, display graphs, and perform test operations, etc., on the personal computer.
8.1.1 Specifications
Item Description
Communication signal
RS-232C
Baud rate [bps]
57600/38400/19200/9600
Monitor
Display all, high-speed display, graph display
(Minimum resolution changes with the processing speed of the personal computer.)
Alarm
Display, history, amplifier data
Diagnosis
DI/DO display, display of the reason for no rotation, power ON cumulative display, software
No. display,
motor information display, tuning data display, ABS data display, VC automatic offset display,
axis name setting
Parameter
Parameter list, turning, change list, detailed information
Test operation
JOG operation, positioning operation, motor-less operation, DO forced output, and program
operation
Advanced function
Machine analyzer gain search, machine simulation
File operation
Data read, save, print
Others
Automatic operation, station number setting, help display
8.2 MR-J4-Series MR Configurator2
POINT
MR-J4-_A_-RJ servo amplifiers are supported with software version 1.19V or
later.
MR Configurator2 (SW1DNC-MRC2-E) uses the communication function of the servo amplifier to perform
parameter setting changes, graph display, test operation, etc. on a personal computer.
8.2.1 Specifications
Item Description
Project
Create/read/save/delete project, system setting, and print
Parameter
Parameter setting, amplifier axis name setting, parameter converter (Note 1)
Positioning data (Note 2)
Point table, program, indirect addressing
Monitor
Display all, I/O monitor, graph, and ABS data display
Diagnostics
Alarm display, alarm onset data display, drive recorder, display of the reason for no rotation,
system configuration, life diagnosis, machine diagnosis
Test operation
JOG operation, positioning operation, motor-less operation, DO forced output, and program operation,
Test operation event information, single-step feed (Note 2)
Adjustment
One-touch tuning, tuning, and machine analyzer
Others
Servo assistant, parameter setting range update, help display, connection to MITSUBISHI ELECTRIC
FA Global Website
Note 1. This function is available only in standard control mode.
2. This function is available only for MR-J4-_A_-RJ.
Содержание MELSERVO-J2-Super Series
Страница 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Страница 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Страница 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Страница 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Страница 219: ...Part 5 Review on Replacement of MR J2S 30 kW or Higher Capacity Models with MR J4 DU_ 5 58 MEMO ...
Страница 220: ...Part 6 Review on Replacement of MR J2M with MR J4 6 1 Part 6 Review on Replacement of MR J2M with MR J4 ...
Страница 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Страница 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Страница 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Страница 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Страница 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Страница 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Страница 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...
Страница 464: ... Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 Appendix 1 1 Appendix 1 Summary of MR J4_B_ RJ020 MR J4 T20 ...