626
20.3
Bus Master Interface
ADDRA to ADDRD are 16-bit registers, but they are connected to the bus master by the upper 8
bits of the 16-bit peripheral data bus. Therefore, although the upper byte can be accessed directly
by the bus master, the lower byte is read through an 8-bit temporary register (TEMP).
An A/D data register is read as follows. When the upper byte is read, the upper-byte value is
transferred directly to the bus master and the lower-byte value is transferred into TEMP. Next,
when the lower byte is read, the TEMP contents are transferred to the bus master.
When reading an A/D data register, always read the upper byte before the lower byte. It is possible
to read only the upper byte, but if only the lower byte is read, the read value is not guaranteed.
Figure 20.2 shows the data flow for access to an A/D data register.
See section 20.7.3, Access Size and Read Data.
Bus
interface
TEMP
[H'40]
ADDRn L
[H'40]
ADDRn H
[H'AA]
CPU
(H'AA)
Upper byte read
Module internal data bus
Bus
interface
TEMP
[H'40]
ADDRn L
[H'40]
ADDRn H
[H'AA]
n = A to D
CPU
(H'40)
Lower byte read
Module internal data bus
Figure 20.2 A/D Data Register Access Operation (Reading H'AA40)
Содержание SH7709S
Страница 2: ...Hitachi SuperH RISC engine SH7709S Hardware Manual ADE 602 250 Rev 1 0 09 21 01 Hitachi Ltd ...
Страница 75: ...56 ...
Страница 107: ...88 ...
Страница 125: ...106 ...
Страница 139: ...120 ...
Страница 203: ...184 ...
Страница 245: ...226 ...
Страница 292: ...273 T1 CKIO A25 to A0 CSn RD WR RD D31 to D0 WEn D31 to D0 BS T2 Read Write Figure 10 6 Basic Timing of Basic Interface ...
Страница 323: ...304 Tp TRr TRrw TRrw CKIO CKE CSn RAS3U RAS3L CASU CASL RD WR Figure 10 28 Synchronous DRAM Auto Refresh Timing ...
Страница 411: ...392 ...
Страница 609: ...590 ...
Страница 635: ...616 ...
Страница 663: ...644 ...
Страница 679: ...660 ...