background image

DC

SRV 2

SRV 1

X3

X2

X1

X5

X9

X6

X10

X7

X11

X8

X12

X4

©

W

estermo 

Teleindustri 

AB

12-port Ethernet M12 switch / GigE

www.westermo.com

User Guide

6641-2242

DC

CON

FRNT

RSTP

X3

X2

ON

USB

X1

X5

X9

X6

X10

X7

X11

X8

X12

X4

Viper-12 

S E R I E S

Содержание Viper-012

Страница 1: ...3 X2 X1 X5 X9 X6 X10 X7 X11 X8 X12 X4 Westermo Teleindustri AB 12 port Ethernet M12 switch GigE www westermo com User Guide 6641 2242 DC CON FRNT RSTP X3 X2 ON USB X1 X5 X9 X6 X10 X7 X11 X8 X12 X4 Viper 12 S E R I E S ...

Страница 2: ...ot limited to the implied warranties of merchantability and fitness for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequenti...

Страница 3: ...mbient temperature is within the specified temperature range e g by avoiding obstruction of the airflow around the unit Also check chapter CEN TS 45545 2 mounting notes Before mounting using or removing this unit Prevent access to hazardous voltage by disconnecting the unit from all power supply WARNING Do not open connected unit Hazardous voltage may occur within this unit when connected to power...

Страница 4: ...id water beverages paint etc unless all connectors are connected or fitted with protective caps delivered with the unit tightened to the specified torque Connected cables must have the appropriate ingress protection code Do not use or store the unit in dusty or dirty areas unless all connectors and the ventilation membrane are sufficiently protected Do not cover or bring mechanical force to the ve...

Страница 5: ...e This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause ha...

Страница 6: ... EN 50121 3 2 Railway applications Electromagnetic compatibility Rolling stock Apparatus 2015 EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signaling and telecommunications apparatus 2015 EN 61000 6 1 Electromagnetic compatibility Generic standards Immunity for residential commercial and light industrial environments 2007 EN 61000 6 2 Electromagnetic co...

Страница 7: ...pplications Electromagnetic compatibility Rolling stock Apparatus 2006 EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signaling and telecommunications apparatus 2006 EN 61000 6 1 Electromagnetic compatibility Generic standards Immunity for residential commercial and light industrial environments 2007 EN 61000 6 2 Electromagnetic compatibility Generic sta...

Страница 8: ...strength EN 60950 1 Power port to all other ports 1 5 kV ACrms 50 Hz 1 min Fast Ethernet ports to all other ports 1 5 kVACrms 50 Hz 1 min Gig Ethernet ports to all other ports 500 VACrms 50 Hz 1 min Environmental Temperatures EN 60068 2 1 EN 60068 2 2 Operating 40 to 70 C 40 to 158 F Storage and transport 50 to 85 C 58 to 185 F Humidity EN 60068 2 30 Operating 5 to 95 relative humidity Storage and...

Страница 9: ...llows a video stream to reconfigure very fast Advanced functionality for VLANs with support for up to 64 virtual networks combined with real time properties is implemented in the switch in order to achieve determinism for real time critical applications Made easy and secure configuration You can safely access your switch from anywhere in the network or directly to the product via a console port Th...

Страница 10: ...r proper start up X1 X12 Ethernet ports Electrical specification IEEE std 802 3 2005 Edition Data rate 10 Mbit s 100 Mbit s manual or auto Duplex Full or half manual or auto Circuit type Viper x12 X1 X12 TNV 1 Viper x12 T3G X1 X3 X5 X7 X9 X11 TNV 1 X4 X8 X12 SELV Transmission range Up to 150 m with CAT5e cable or better Isolation to Viper x12 1500 VAC rms to all other ports Viper x12 T3G X1 X3 X5 ...

Страница 11: ...Electrical specification USB 2 0 host interface Data rate Up to 480 Mbit s high speed mode Maximum supply current 500 mA Circuit type SELV Isolation to Ethernet ports 1500 VAC rms DC 1500 VAC rms No isolation to CON Connection 5 pin M12 female A code use Westermo USB plug 3641 0190 CON Console port Electrical specification RS 232 Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit ...

Страница 12: ...face ports and LED s Viper 012 112 212 DC CON FRNT RSTP ON USB X1 X5 X9 X6 X10 X7 X11 X8 X12 X2 X3 X4 Ethernet connection TX Power connection LED indicators for details see page 15 Earth connection Console connection USB connection ...

Страница 13: ... X2 X3 X4 DC SRV 1 SRV 2 X1 X5 X9 X6 X10 X7 X11 X8 X12 X2 X3 X4 SRV 1 SRV 2 only for internal use byWestermo staff Power Pin number Signal 2 1 3 4 No 1 DC1 No 2 DC2 No 3 COM No 4 COM USB Pin number Signal No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND CON Pin number Signal No 1 NC No 2 TX No 3 RX No 4 NC No 5 GND ...

Страница 14: ...4 6641 2242 Location of interface ports and LED s Viper 112 212 T3G Ethernet connection TX Power connection LED indicators for details see page 15 Earth connection Console connection USB connection GigE ...

Страница 15: ...C1 No 2 DC2 No 3 COM No 4 COM Viper x12 T3G supports redundant power connection The positive inputs are DC1 and DC2 the negative input for both supplies are COM USB Pin number Signal No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND CON Pin number Signal No 1 NC No 2 TX No 3 RX No 4 NC No 5 GND GigE X4 X8 X12 Pin number Signal 1 2 3 4 5 6 7 8 1 DA 2 DA 3 DB 4 DB 5 DD 6 DD 7 DC 8 DC ...

Страница 16: ...h correct speed and format 115200 8N1 to the assigned port For more information about the CLI see the WeOS management guide Connection to USB port Viper 112 212 112 212 T3G Managed only The USB port can be used to copy configuration and log files to from the switch The following steps needs to be taken 1 Connect the USB plug use Westermo USB plug 3641 0190 to the USB port 2 Access the switch CLI v...

Страница 17: ...ated when connected to IPConfig Tool or when configuring the unit via Web or CLI DC OFF Unit has no power GREEN Power OK on DC1 and DC1 RED Power failure on DC1 or DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch X1 to X12 OFF No Link GREEN Link established GREEN FL...

Страница 18: ...s installed so that the ambient temperature is within the specified temperature range e g by avoiding obstruction of the airflow around the unit CEN TS 45545 2 mounting notes Two Viper units can be mounted together and as a single interior non listed group in the sense of CEN TS 45545 2 definitions For multiple units the spacing requirements for interior non listed groups must be met Wall mounting...

Страница 19: ... the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via web browser The unit can easily be configured via a web browser Open the link http 192 168 2 200 in your web browser and you will be prompted with a Login screen where the default...

Страница 20: ...o go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cables The ON LED will stop flashing This initiates the factory reset process and after approximately 1 minute the unit will restart with factory default settings When the switch has booted up the ON LED will sho...

Страница 21: ... 24 23 3 48 48 8 73 5 72 14 54 1 1 65 4 1 Material Remark Designation Dimension Description Quantity Pos No 1 1 Scale Status Designer Drawing No PaPu Approved 6001 0001 U 01 Sheet 1 1 Denomination Viper 12 series Dimensional Drawing 2010 Westermo Teleindutri AB All rights reserved Approved Date 130225 Description Designer Rev Date Approved ToDu PaPu 01 Created 130225 ToDu ...

Страница 22: ...ce infos westermo fr www westermo fr Germany info westermo de www westermo de North America info westermo us www westermo us Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 ...

Отзывы: