Serial Data Reception: The processing procedures in smart card mode are the same as in ordinary
SCI processing. The reception processing flowchart is shown in figure 15.7.
1. Initialize the smart card interface mode as described above in Initialization and in figure 15.5.
2. Check that the ORER and PER flags in SCSSR are cleared to 0. If either flag is set, clear both
to 0 after performing the appropriate error handling procedures.
3. Repeat steps 2 and 3 until the RDRF flag is set to 1.
4. Read the receive data from SCRDR.
5. To receive more data, clear the RDRF flag to 0 and return to step 2.
6. To end reception, clear the RE bit to 0.
This processing can be interrupted. When the RIE bit is set to 1 and interrupt requests are enabled,
a receive-data-full interrupt (RXI) will be requested when the RDRF flag is set to 1 at the end of
reception. When an error occurs during reception and either the ORER or PER flag is set to 1, a
communication error interrupt (ERI) will be requested. See Interrupt Operation below for more
information.
The received data will be transferred to SCRDR even when a parity error occurs during reception
and PER is set to 1, so this data can still be read.
Содержание SH7709S
Страница 2: ...Hitachi SuperH RISC engine SH7709S Hardware Manual ADE 602 250 Rev 1 0 09 21 01 Hitachi Ltd ...
Страница 75: ...56 ...
Страница 107: ...88 ...
Страница 125: ...106 ...
Страница 139: ...120 ...
Страница 203: ...184 ...
Страница 245: ...226 ...
Страница 292: ...273 T1 CKIO A25 to A0 CSn RD WR RD D31 to D0 WEn D31 to D0 BS T2 Read Write Figure 10 6 Basic Timing of Basic Interface ...
Страница 323: ...304 Tp TRr TRrw TRrw CKIO CKE CSn RAS3U RAS3L CASU CASL RD WR Figure 10 28 Synchronous DRAM Auto Refresh Timing ...
Страница 411: ...392 ...
Страница 609: ...590 ...
Страница 635: ...616 ...
Страница 663: ...644 ...
Страница 679: ...660 ...