7-40
Operating Modes
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The result is the following time diagram:
v
x
x
0
1
0
1
0
1
0
DK000056v01_en.fh7
pos. cmd val.
act. pos. val.
target position
starting position
lag error
(drawing
magnified)
S-0-0013, bit 12
target position
attained
S-0-0437, bit 1
in target position
actual velocity
value
S-0-0437, bit 2
IZP
t
t
t
t
t
t
t
positioning
window
positioning
window
positioning
window
standstill
window
Fig. 7-23:
Generating the status bits of the operating modes with drive-internal
interpolation
7.7
Positioning Block Mode
Brief Description
In the "positioning block mode" it is possible to run up to 64 programmed
positioning blocks. The drive moves to the target position in position
control, while maintaining velocity, acceleration, deceleration and jerk
limits as defined in the respective positioning block.
torque/force
cmd value
velocity cmd
value
effective
pos. cmd value
positioning
block
positioning
generator
position
controller
current
controller
target
position
DF000087v01_en.fh7
M
velocity
controller
cmd value
interpolation
Fig. 7-24:
"Positioning block mode" block diagram
Base package
of all variants in
closed-loop
characteristic