8-64
Drive Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Pertinent parameters:
•
P-0-0402, Axis correction reference temperature
•
P-0-0403, Axis correction reference position for temp. corr.
•
P-0-0404, Axis correction actual temperature pos.-dependent
•
P-0-0406, Axis correction temperature factor pos.-dependent
Ap5046f3.fh7
servo drive
tool
slide
"point of reference"
®
not temperature-dependent
locating bearing
actual pos. value with pos.-
dependent position error,
when
J
axis
¹
J
reference
Fig. 8-50:
Example of application for position-dependent temperature
correction
Note:
The actual position value system to be corrected is selected
via the respective bit of
P-0-0413, Axis correction control
word
.
Operating principle of position-dependent temperature correction:
act. pos. val.
correction value internal
act. pos. val., corrected
refer. position
temp. factor,
pos.-dependent
actual temp.,
pos.-dependent
reference
temperature
Fig. 8-51:
Position-dependent temperature correction