8-46
Drive Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Note:
This change bit is cleared again by reading
S-0-0012, Class 2
diagnostics
. Using parameter
S-0-0097, Mask class
2
diagnostic
warnings can be adjusted in terms of their effect
on the change bit.
Note:
To reactivate the drive, the E-Stop input must be deactivated
and
another positive edge
must be applied
to the external
drive enable
.
If the interpretation was set as an error in P-0-0008 (bit 2 = 0), the
reaction selected in bit 1 is carried out:
•
The diagnostic error message
F4034 Emergency-Stop
(or
F6034
Emergency-Stop
) appears.
•
Bit 15 is set in parameter
S-0-0011, Class 1 diagnostics
.
•
Bit 13 (drive interlock, error in class 1 diagnostics) is set in the drive
status word of the drive telegram. The error message can be cleared
via command
S-0-0099, C0500 Reset class 1 diagnostics
or the
"Esc" button of the control panel if the E-Stop input is no longer active.
Note:
The error reaction is carried out without delay, independent of
parameter
P-0-0117, Activation of NC reaction on error
.
If bit 1 = 0 was set in parameter P-0-0008, the drive is shut down
according to the error reaction parameterized via
P-0-0119, Best
possible deceleration
.
The diagnostic message upon activating the E-Stop input then reads
F4034 Emergency-Stop
.
If bit 1 = 1 was set in parameter P-0-0008, the drive, when the E-Stop
triggers, is braked with maximum torque to speed = 0, independent of the
error reaction defined in parameter P-0-0119. This setting corresponds to
the best possible deceleration "velocity command value reset".
The diagnostic message upon activating the E-Stop input then reads
F6034 Emergency-Stop
.
Notes on Commissioning
Activation and Polarity of the E-Stop Input
Prerequisite for using the function is the assignment of bit 0 of parameter
P-0-0223 to a digital input (see "Digital Inputs/Outputs: Notes on
Commissioning" in chapter "Extended Drive Functions"). A voltage level
at the digital input therefore also affects bit 0 of P-0-0223.
Note:
Without this assignment to the digital input the E-Stop reaction
fails to occur in spite of the input having been activated!
The activation of the E-Stop input and the selection of a reaction for
shutdown of the drive is carried out via bit 0 of parameter
P-0-0008,
Activation E-Stop function
(see also Parameter Description P-0-0008).
P-0-0008, bit 0 (activation E-Stop):
•
bit 0 = 0
→
function not activated
•
bit 0 = 1
→
function activated
E-Stop Reaction
P-0-0008, Bit 1
Assigning Digital Input
Activating E-Stop
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪