MPH-02, MPB-02, MPD-02
Drive Control
6-81
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The figures below illustrates the principle of central supply:
module bus
module bus
module bus
L +
L -
+24 V
0 V
DF000122v01_en.fh7
3
mains connection
control voltage
power voltage
(DC bus)
supply unit
inverter
inverter
inverter
Fig. 6-54:
Mains supply via supply unit
module bus
module bus
module bus
L +
L -
+24 V
0 V
DF000123v01_en.fh7
3
mains connection
control voltage
power voltage
(DC bus)
converter
inverter
inverter
converter
Fig. 6-55:
Mains supply via converter
Note:
The following possibilities and restrictions have to be
observed:
•
IndraDrive M inverters can be connected to IndraDrive C
converters! Take DC bus power into account!
•
Further HCS02.1 converters that are operated as inverters
may be connected to IndraDrive C devices (converter
HCS02.1).
Exception: There mustn’t be any further HCS03.1 devices
be connected to HCS03.1 devices (inverter operation)!
Central Supply