7-26
Operating Modes
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Diagnostic Messages and Monitoring Functions
Diagnostic Status Messages
The activated "drive-internal interpolation" mode is displayed by one of the
following diagnostic messages:
•
A0106 Drive controlled interpolation, encoder 1
•
A0107 Drive controlled interpolation, encoder 2
•
A0108 Drive controlled interpolation, lagless, encoder 1
•
A0109 Drive controlled interpolation, lagless, encoder 2
Monitoring Functions
Operating mode-specific monitoring functions are:
•
If position limit value monitoring is activated (bit 4 of
S-0-0055,
Position polarities
is set) and the measurement system used for the
operating mode has been homed, the parameter
S-0-0258, Target
position
is monitored for complying with the position limit values
(S-0-0049 or S-0-0050). If these values are exceeded, the
E2053
Target position out of travel range
warning is generated.
The preset target position will not be accepted.
•
If the positioning velocity preset in
S-0-0259, Positioning Velocity
equals zero, the
E2047 Interpolation velocity
=
0
warning is
generated.
•
If the positioning velocity preset in
S-0-0260, Positioning
Acceleration
equals zero, the
E2048 Interpolation acceleration = 0
warning is generated.
•
If the preset positioning velocity (
S-0-0259, Positioning Velocity
)
exceeds the maximum allowed limit value (
S-0-0091, Bipolar velocity
limit value
), the
E2049 Positioning velocity >= S-0-0091
warning is
generated.
The drive will move to the new target position with the velocity from
parameter
S-0-0091, Bipolar velocity limit value
.
•
If the factor of the positioning velocity
S-0-0108, Feedrate override
equals zero, the
E2055 Feedrate override S-0-0108 = 0
warning is
generated.
Status Messages
The
S-0-0437, Positioning status word
parameter contains all important
status information for this "drive-internal interpolation" mode.
See Parameter Description "S-0-0437, Positioning status word"
E2053 Target position out of
travel range
E2047 Interpolation velocity = 0
E2048 Interpolation acceleration
= 0
E2049 Positioning velocity >=
S-0-0091
E2055 Feedrate override
S-0-0108 = 0
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com