background image

AR3600I

AC LINE VOLTAGE REGULATOR

User  Instructions

This booklet contains important information concerning the proper and safe operation of your new amplifier..

Index

01 General Information

04 Installation

   05 Operation

10 Specification

INPUT  VOLTAGE

OUTPUT  VOLTAGE

L

N

REGULATED

OUTPUTS

5%

OVER

IN

REGULATION

5%

UNDER

OUTPUT  CURRENT

UNiKA

P  R  O  F  E  S  S  I  O  N  A  L    A  U  D  I  O

AR

-

3600

I

INPUT RANGE:

88-264VAC 30A MAXIMUM

O

T  

 

R

S

E

S

S

E

E

R

T

P

           L I N E    R E G U L A T O R

          1 2 0 V   3 0 A   O U T P U T

          A C .

P R O F E S S I O N A L 

A U D I O

Содержание AR3600I

Страница 1: ...ex 01 General Information 04 Installation 05 Operation 10 Specification INPUT VOLTAGE OUTPUT VOLTAGE L N REGULATED OUTPUTS 5 OVER IN REGULATION 5 UNDER OUTPUT CURRENT UNiKA P R O F E S S I O N A L A U D I O AR 3600 I INPUT RANGE 88 264VAC 30A MAXIMUM O T R S E S S E E R T P L I N E R E G U L A T O R 1 2 0 V 3 0 A O U T P U T A C P R O F E S S I O N A L A U D I O ...

Страница 2: ...laceable parts inside Please contact the authorized dealer for any requirements on technical support 3 The AR3600I is a complex electronic instrument with various wiring options You cannot simply plug in and go Take the time to read this manual especially the sections on Installation and Operation For any questions in doubt please contact the authorized dealer for further assistance GENERAL INFORM...

Страница 3: ...e Figure 1 The AR 3600I can handle loads totaling up to 30 amperes as long as the input voltage is equal to or above 120 volts low range or 240 volts high range For voltages below those levels its capacity must be derated at approximately one quarter ampere per volt See Figure 2 below In live performance situations where each act requires a special AC configuration accidental connection to incorre...

Страница 4: ...n off switch One or more units may be turned on remotely either simultaneously or in sequence by switching an internally derived DC control line The AR 3600I is housed in a three space 5 2 high and 17 deep rack mount chassis and weighs only 53 lbs 24 kg It is made of extremely rugged heavy gauge black powder coat steel Allow it to be secured in both front and rear It comes equipped with a male IEC...

Страница 5: ...able is highly recommended for best flexibility and abrasion resistance It is permissible to use 4 conductor cable but it is not necessary to do so and is not recommended EFFECTS OF CABLE LENGTH When dealing with high currents such as those handled by the AR3600I the supply cable itself must be considered part of the load As such the length gauge and temperature rating of the insulation must be ta...

Страница 6: ...rews which may fit if forced but will strip the threads To avoid marring the front panel finish use plastic washers under the screw heads OPERATION FRONT PANEL FEATURES INPUT VOLTMETER Large size 7 segment 3 digit LED display indicate the input voltage in either of two ranges The appropriate range is selected automatically OUTPUT AMMETER Large size 7 segment 3 digit LED display with decimal indica...

Страница 7: ...o produce the rated 120V 30A at the output Therefore safety considerations require a separate 15A breaker which is active only when a high range 170 volts or higher supply voltage is used This breaker trips by popping out If it trips decrease the load on the AR3600I and push it in to reset POWER SWITCH This is the AR3600I s main on off switch It is actually a 30 ampere magnetic trip circuit breake...

Страница 8: ...red up simultaneously Using such a delayed sequence can avoid blowing a house breaker when all the A3600Is are powered from the same circuit See the section on Remote Delayed Operation later in this manual for details Note No connections or jumpers are needed for normal AR3600I operation REGULATED OUTLETS There are 7 regulated outlets on the AR3600I one in front and the balance in the rear While t...

Страница 9: ...R3600Is remote turn on in delayed sequence A built in delay of approximately a quarter second is automatically provided to stagger the potentially large inrush currents that occur when certain types of equipment are powered up simultaneously Using such a delayed sequence can avoid blowing a house breaker when all the AR3600Is are powered from the same circuit To create a remote delayed sequence al...

Страница 10: ...n also foul switch contacts and degrade wiring insulation They are an unavoidable component of electric power They are caused unpredictably by electric motors switching on or off on the premises or outside utility company maintenance operations lightning strikes and other factors Spikes also called surges or transients are absorbed by special components in the AR3600I to provide safe voltage level...

Страница 11: ...nd line to ground Clamping Voltage line to neutral neutral to ground 250 Volts peak 130V rms 184V peak Clamping Voltage line to ground 500 Volts peak Response time 1 nanosecond Maximum surge current 5 000 amps 8 x 20 ps pulse Maximum spike energy 455 joules total Noise attenuation Transverse 50 dB 1 to 120 MHZ Dimensions 132mm H x 483mm W x 428mm D Weight 24Kg Construction All steel chassis powder...

Страница 12: ...ules not included to terminate stranded wire in coupling connector General Information Installation Operation Specification AR3600I AC LINE VOLTAGE REGULATOR Figure 7 Blue 32A 3 Contact High Current In line Socket Figure 8 Blue 32A 3 Contact High Current In line Plug A male IEC 60309 cable mounting power inlet is also included with your AR3600I Neutral N Live Hot L Ground G Live Hot L Ground G Neu...

Страница 13: ......

Страница 14: ...P R O F E S S I O N A L A U D I O ...

Отзывы: