MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-37
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Notes on Commissioning
CAUTION
Property damage caused by command-
dependent activation of motors and moving
elements!
⇒
Bring axis resp. moving parts in safe initial position;
limit travel range and drive power!
Note:
By pressing the "Esc" button again the standard display will
reappear.
Note:
The input via the buttons is polled in an 8 ms-cycle, the display
is updated in an 8 ms-cycle, too.
10.5 MultiMediaCard (MMC)
Brief Description
The MultiMediaCard (MMC) is a non-volatile storage medium that can be
inserted in the slot provided for this purpose on the front of the controller.
The MMC can store drive firmware, drive parameters and other files. The
MMC can be used optionally.
As
stationarily
(permanently) plugged storage medium the
MMC
can be
used as:
•
"programming module", as active, non-volatile memory containing the
current axis-specific parameter values and the firmware active in the
drive.
As a
temporarily
plugged storage medium the
MMC
can be used for:
•
updating firmware via command,
•
transmitting drive parameter sets and firmware to other drives for
serial commissioning via command,
•
saving the parameter values after initial commissioning,
•
reestablishing the original parameter status of the drive (loading the
saved parameter values).
Attention:
Not for drives with absolute value encoder and modulo format!
See also "Initial Commissioning/Serial Commissioning" in chapter
"Commissioning"
Note:
The MMC commands can be started via the control panel.
This is especially advantageous when replacing devices!
Note:
It is only allowed to use MMCs by Bosch Rexroth (type
designation PFM02.1-0016-FW)!