MPH-02, MPB-02, MPD-02
Master Communication
4-69
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
•
in target position during spindle positioning
(
S-0-0336, Message In position
)
•
torque limit value reached (
S-0-0334, Message ’T >= Tlimit’
)
•
torque threshold exceeded (
S-0-0333, Message ’T >= Tx’
)
•
speed threshold exceeded
(
S-0-0335, Message ’n command > n limit’
)
•
power threshold exceeded (
S-0-0337, Message ’P >= Px’
)
See also descriptions of the respective parameters in the separate
documentation ""Rexroth IndraDrive, Parameter Description".
Bit in
signal status
word
Configured
parameter
Configured bit
in parameter
Function/
significance
1
S-0-0330
0
n_actual =
n_command
2
S-0-0331
0
n_feedback = 0
3
S-0-0332
0
nactual < nx
4
S-0-0333
0
T >= Tx
5
S-0-0334
0
T >= Tlimit
6
S-0-0335
0
n command > n
limit
7
S-0-0336
0
In_Position
8
S-0-0337
0
P >= Px
9
--
--
10
--
--
11
--
--
12
--
--
13
--
--
14
--
--
15
--
--
Fig. 4-43:
Example of configuration for main spindle messages via digital
outputs
The following
command
is relevant for main spindle drives:
•
C0900 Position spindle command
(S-0-0152)
Bit in
signal status
word
Configured
parameter
Configured bit
in parameter
Function/
significance
1
S-0-0152
0
spindle positioning
2
--
--
…
…
…
15
--
--
Fig. 4-44:
Example of configuration for main spindle command drive via digital
inputs
See also "Spindle Positioning" in chapter "Drive Functions"