DOK-INDRV*-MP*-02VRS**-FK01-EN-P
S-0-0025, IDN-list of all procedure commands
The IDNs of all the command parameters available in the drive are stored
in the operating data of the
S-0-0025, IDN-list of all procedure
commands
parameter.
S-0-0270, Selected IDN list of operation data to backup
The IDNs of those parameters are stored in the
S-0-0270, Selected IDN
list of operation data to backup
parameter that are to be saved when
the
S-0-0293, C2400 Selectively backup working memory procedure
command
is executed.
S-0-0279, IDN-list of password-protected operation data
The
S-0-0279, IDN-list of password-protected operation data
parameter contains the IDNs of those parameters that can be protected
by a customer password (S-0-0267). By default there haven’t been any
IDNs entered in this parameter.
S-0-0327, IDN list of checksum parameter
The parameter
S-0-0327, IDN-List of checksum parameter
contains the
IDNs of those parameters from which the content of parameter
S-0-0326,
Parameter checksum
is to be generated. By default there haven’t been
any IDNs entered in this parameter.
P-0-0013, List of all IDNs not corresponding to default
value
All parameters the operating data of which was changed with regard to
the default value are stored in parameter
P-0-0013, List of all IDNs not
corresponding to default value
.
Using a Password
Brief Description
IndraDrive controllers provide the possibility to protect parameter values
against accidental or unauthorized change by means of a password. With
regard to write protection, there are 3 groups of parameters that can be
written:
•
Parameters that are write-protected as a standard, such as motor
parameters, hardware code parameters, encoder parameters, error
memory etc. ("administration parameters"). The values of these
parameters guarantee correct function and performance of the drive.
•
Parameters the customer can combine in groups and protect them
with a so-called customer password. This allows protecting parameter
values, that are used for adjusting the drive to the axis, after having
determined them.
•
All other parameters that can be written and are not contained in the
above-mentioned groups. They are not write-protected.