10-8
Handling, Diagnostic and Service Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
To load saved parameter values or transmit axis-specific parameter
values to controllers of other axes there are the following possibilities:
•
Start
P-0-4091, C2500 Copy IDN from optional memory to internal
memory
The parameter values (according to list of S-0-0192) stored on a
plugged MMC are loaded to the device-internal, non-volatile flash
memory.
•
"DriveTop" commissioning tool
The parameter values (according to list of S-0-0192) stored on an
external data carrier (hard disk, floppy disk or the like) are loaded to
the controller; source assignment is carried out via the menu of the
tool (serial communication with the controller or via SERCANS-
Box/SERCOS interface).
•
Control master
The parameter values of the list of S-0-0192 or S-0-0270 and/or other
parameters, if necessary, are loaded to the controller from a master-
side data carrier by command of the control master.
When reading the
S-0-0326, Parameter checksum
parameter the
checksum of all parameter values is generated the IDNs of which are
contained in parameter
S-0-0327, IDN list of checksum parameter
.
Changes in the parameter settings can be detected by comparing the
checksums.
By comparing the checksum of the parameter values currently active in
the drive to a checksum value stored at the time of parameter saving, it is
possible to determine whether the active application-specific parameter
values are correct.
By default there haven’t any IDNs been entered in parameter S-0-0327!
Notes on Commissioning
At the beginning of the initial commissioning of a motor or a machine axis,
first make sure the desired firmware is active in the drive. To do this, read
parameter
•
S-0-0030, Manufacturer version
.
If the desired firmware is not available in the controller, carry out a
firmware update (see "Firmware Update" in chapter "Handling, Diagnostic
and Service Functions").
If the desired firmware is available in the controller, load basic parameter
values of the firmware:
1. set
P-0-4090, Index for C07 Load defaults procedure
2. start
S-0-0262, C07_x Load defaults procedure command
Respective diagnostic command message:
•
C07_1 Load defaults procedure com. (load basic parameters)
Respective diagnostic messages in the case of possible command errors:
•
C0751 Parameter default value incorrect (-> S-0-0021)
•
C0752 Locked with password
•
C0753 ’Load basic parameters’ not allowed in phases 3 and 4
See also "Initial Commissioning/Serial Commissioning" in chapter
"Commissioning"
Loading Application-Specific
Parameter Values
Parameter Checksum
Initial Commissioning
Load Basic Parameters