4-2
Master Communication
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The address is set via the control panel as follows:
1. change to "commands/settings" mode
1.Er.Anz
1 F2002
standard display
press "Enter"
and "Esc"
buttons for
8 seconds
extended display
2.Comand
"Up" button
commands/settings
e.g.:
Fig. 4-2:
Activating the "commands/settings" mode
2. select element "2.1 drive address" by means of "Up/Down" buttons,
then confirm by means of "Enter" button
3. set drive address by means of "Up/Down" buttons, then confirm by
means of "Enter" button
•
first
set
tens digit
:
→
the display reads "2.1.1 drive address"
•
then
set
units digit
:
→
the display reads "2.1.2 drive address"
Note:
The tens or units digit is accepted by pressing the "Enter"
button. To return press the "Esc" button.
1.Er.Anz
extended display
"Enter" button
"Esc" button
display
2.1 Adr.
drive address
Y.Y
XXXXXXXX
explanation:
2.Comand
commands/settings
"Down" button
"Up" button
"Enter" button
"Esc" button
2.1.1
Z
E
display
2.1.2
Z
E
display
"Enter" button
"Esc" button
accept with "Enter" button
set units digit with "Up/Down"
buttons
set tens digit with "Up/Down"
buttons
ZE … tens/units ("
Z
ehner/
E
iner") digit of drive
address
display changes (flashes)
between "Y.Y" and "XXXXXXXX"
Fig. 4-3:
Selecting and setting the drive address
Address Setting via Parameter
The drive address can also be set by writing the
P-0-4025, Drive address
of master communication
parameter. This is particularly interesting if
you administrate the axis data in centralized form in the control unit and
want to set the address from the control unit when replacing devices.
See also "Notes on How to Replace the Devices" in chapter "Handling,
Diagnostic and Service Functions"