MPH-02, MPB-02, MPD-02
Motor, Mechanical Axis System, Measuring Systems
5-11
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
1
0
released
applied
(AF internal)
DK000009v01_en.fh7
Bit 3: 1
0
P-0-0115
Bit 14: 1
0
Bit 15: 1
0
AF from NC
AF reset by NC or error, e.g. with "velocity
command value to zero" error reaction
drive disables NC command values
actual velocity
value
S-0-0273
S-0-0207
t
motor
holding
brake
Fig. 5-5:
Holding brake control with error situation 1 and braking time > S-0-
0273 for servo drives
released
applied
1
0
(AF internal)
DK000010v01_en.fh7
bit 3: 1
0
motor
holding
brake
P-0-0115
bit 14: 1
0
bit 15: 1
0
AF from NC
AF reset by NC or error, e.g. with "velocity
command value to zero" error reaction
drive disables NC command values
10 min
-1
bzw. 10 mm/min
actual velocity
value
S-0-0273
t
Fig. 5-6:
Holding brake control with error situation 1 and braking time > S-0-
0273 for main drives
Note:
If the "return motion" error reaction has not yet been
completed after the time set in S-0-0273, it is aborted:
•
In the case of servo drives, the holding brake is applied.
The internal drive enable is switched off with the delay of
"drive off delay time".
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com